D-Link DFE-2616IX User Guide - Page 70

Group Slot 1, Group Slot 2, Group Isolate

Page 70 highlights

Dual-Speed Stackable Hubs User's Guide hh:mm:ss.xx, with hh representing hours since the master hub was turned on, mm the minutes, ss the seconds, and xx representing 100ths of a second. ♦ Group Slot (1). Shows the status of module slot 1. If there is a module installed in slot 1, this field will display: MII, TP, FX, or Switch as determined by the type of module installed. If there is no module installed, the field will display one." ♦ Group Slot (2). Shows the status of module slot 2. If there is a module installed in slot 2, this field will display: MII, TP, FX, or Switch as determined by the type of module installed. If there is no module installed, the field will display one." ♦ Group Isolate. Provides control of the hub current network connection status and allows the system manager to manually isolate a particular hub as needed and reconnect it later. Toggling the field to solate" separates the hub data connection from the other hubs. Toggling the field to econnect" re-establishes the connection. See egmenting Hubs" earlier in this chapter for more information. DFE-2600 Stackable Hub - Network Monitoring : Group Configuration Menu Group ID (1-5) [1] Group Serial Number: Group Position Number: Group Description: Group Role: Group Port Capacity: Group Hardware Revision: Group Master Revision: Group Status: Group Last Oper Change: Group Slot (1): Group Slot (2): 623000B DFE2624i Primary Master 24 Rev. 06 Rev. 01 Up 0:1:35.90 Switch none Group Isolate: PREV GROUP NEXT GROUP HELP SAVE EXIT 58 Master Hub Setup and Management

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147

Dual-Speed Stackable Hubs User’s Guide
Master Hub Setup and Management
58
hh:mm:ss.xx, with hh representing hours since the master hub was
turned on, mm the minutes, ss the seconds, and xx representing 100ths
of a second.
Group Slot (1)
.
Shows the status of module slot 1.
If there is a mod-
ule installed in slot 1, this field will display: MII, TP, FX, or Switch as
determined by the type of module installed.
If there is no module in-
stalled, the field will display
one.”
Group Slot (2)
.
Shows the status of module slot 2.
If there is a mod-
ule installed in slot 2, this field will display: MII, TP, FX, or Switch as
determined by the type of module installed.
If there is no module in-
stalled, the field will display
one.”
Group Isolate
.
Provides control of the hub
current network con-
nection status and allows the system manager to manually isolate a
particular hub as needed and reconnect it later.
Toggling the field to
solate” separates the hub
data connection from the other hubs.
Toggling the field to
econnect” re-establishes the connection.
See
egmenting Hubs” earlier in this chapter for more information.
DFE-2600 Stackable Hub - Network Monitoring : Group Configuration Menu
Group ID (1-5)
[1]
Group Serial Number:
623000B
Group Position Number:
Group Description:
DFE2624i
Group Role:
Primary Master
Group Port Capacity:
24
Group Hardware Revision: Rev. 06
Group Master Revision:
Rev. 01
Group Status:
Up
Group Last Oper Change:
0:1:35.90
Group Slot (1):
Switch
Group Slot (2):
none
Group Isolate:
<Reconnect>
PREV GROUP
NEXT GROUP
HELP
SAVE
EXIT