Planning the Installation Selecting the Location • Carefully check the location where the oven is to be installed. The oven should be placed for convenient access, but away from drafts that may be caused by doors, windows, and heating, ventilation and air conditioning outlets. • Make certain that electrical power can be provided in the selected location. Be certain that proper clearance is provided for the oven door when it is in the open position. Cabinet Cutout • Plan the installation so that all minimum clearances are met or exceeded. Cutout dimensions shown provide minimum clearances, unless otherwise noted. • The specified minimum cabinet depth and width must be provided. The cabinet depth and width must completely enclose the recessed portion of the oven. • Cabinet cutout dimensions must be used as indicated. Model Number A B C EO127 MOH127 MOV127 EO130 MOH130 MOV130 27" 7/16" (69.7 cm) 25 ½" 27" 56 ½" (64.8 cm) (68.6 cm) (143.5 cm) 28 ½" 30" 62 ½" (72.4 cm) (76.2 cm) (158.8 cm) EO227 MOH227 25 ½" 27" (64.8 cm) (68.6 cm) MOV227 50 9/16" EO230 (128.4 cm) NA MOH230 28 ½" 30" (72.4 cm) (76.2 cm) MOV230 Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated. C C Recommended electrical location Recommended electrical location 1" (2.5 cm) min. clear to bottom of door Single Wall Oven Cutout A B Alternate 3/4" (1.9 cm) support platform electrical location 1" (2.5 cm) min. clear to bottom of door A B Double Wall Oven Cutout 1 ¾" (4.5 cm) min. clear to top of door for heat exhaust 1 ¾" (4.5 cm) min. 31 1/4" (79.4 cm) recommended (may be altered) clear to top of door for heat exhaust 3/4" (1.9 cm) support platform 4" typical toe kick (shown) 4" typical toe kick (shown) 9 5/8" (24.4 cm) recommended (may be altered) 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

6
Planning the Installation
Selecting the Location
Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access, but away from drafts that may be caused by
doors, windows, and heating, ventilation and air condi-
tioning outlets.
Make certain that electrical power can be provided in
the selected location. Be certain that proper clearance
is provided for the oven door when it is in the open
position.
Cabinet Cutout
Plan the installation so that all minimum clearances are
met or exceeded. Cutout dimensions shown provide
minimum clearances, unless otherwise noted.
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
Cabinet cutout dimensions must be used as indicated.
A
B
4“ typical toe kick (shown)
3/4” (1.9 cm)
support platform
Recommended
electrical
location
9 5/8” (24.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm) min.
clear to
bottom of
door
C
C
A
B
4“ typical toe kick (shown)
Alternate
electrical
location
3/4” (1.9 cm)
support platform
Recommended
electrical
location
31 1/4” (79.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm)
min. clear to
bottom
of door
Model
Number
A
B
C
EO127
27” 7/16”
(69.7 cm)
25 ½”
(64.8 cm)
27”
(68.6 cm)
56 ½”
(143.5 cm)
MOH127
MOV127
EO130
28 ½”
(72.4 cm)
30”
(76.2 cm)
62 ½”
(158.8 cm)
MOH130
MOV130
EO227
50 9/16”
(128.4 cm)
25 ½”
(64.8 cm)
27”
(68.6 cm)
NA
MOH227
MOV227
EO230
28 ½”
(72.4 cm)
30”
(76.2 cm)
MOH230
MOV230
Single Wall
Oven Cutout
Double Wall
Oven Cutout
Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.