Dell DR6300 DR Series System Command Line Reference Guide - Page 93

disk <slot num>], disk <slot num&gt

Page 93 highlights

Result WARNING: IO to the box will be stopped during enclosure addition. Do you want to continue (yes/no) [n]? y Enclosure: "CTKHVW1" added successfully. system --storage [--set_usage_alert ] Description Used to specify at what storage utilization percentage an alert should be sent. Syntax system --storage --set_usage_alert 90 Result System storage usage alert has been set at 90%. system --storage [--blink] [--type ] [--service_tag ] [-disk ] Description Turns on an LED that is used in locating a specific physical disk or data storage expansion shelf (using the system -storage command) in the DR Series system. Select from the following DR Series system CLI command options: • --blink: turns on LED on the physical disk or expansion shelf to identify it. • --type : identifies storage as an internal physical disk or external expansion shelf. • --service_tag : identifies physical disk or expansion shelf by its unique service tag. • --disk : identifies the disk slot number (if no disk slot is defined, it globally affects all disks). NOTE: There is a counterpart to this command, in which you can turn off the LED that aids in locating the physical disk or expansion shelf. For more information, see system --storage [--unblink] [--type ] [-service_tag>] [--disk ]. NOTE: The above options are only available on a Physical DR. Syntax system --storage --blink --type external --service_tag HCM0PT3 Result Turned on blinking for all disks in enclosure "HCM0PT3". system --storage [--unblink] [--type ] [--service_tag ] [-disk Description Turns off an LED that is used in locating a specific physical disk or data storage expansion shelf (using the system -storage command) in the DR Series system. Select from the following DR Series system CLI command options: • --unblink: turns off LED on the physical disk or expansion shelf. • --type : identifies storage as an internal physical disk or external expansion shelf. • --service_tag : identifies physical disk or expansion shelf by its unique service tag. • --disk : identifies the disk slot number (if no disk slot is defined, it globally affects all disks). 93

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161

Result
WARNING: IO to the box will be stopped during enclosure addition.
Do you want to continue (yes/no) [n]? y
Enclosure: "CTKHVW1" added successfully.
system --storage [--set_usage_alert <70% - 90%>]
Description
Used to specify at what storage utilization percentage an alert should be sent.
Syntax
system --storage --set_usage_alert 90
Result
System storage usage alert has been set at 90%.
system --storage [--blink] [--type <internal | external>] [--service_tag <service tag>] [--
disk <slot num>]
Description
Turns on an LED that is used in locating a specific physical disk or data storage expansion shelf (using the
system --
storage
command) in the DR Series system. Select from the following DR Series system CLI command options:
--blink
: turns on LED on the physical disk or expansion shelf to identify it.
--type <internal | external>
: identifies storage as an internal physical disk or external expansion shelf.
--service_tag <service tag>
: identifies physical disk or expansion shelf by its unique service tag.
--disk <slot num>
: identifies the disk slot number (if no disk slot is defined, it globally affects all disks).
NOTE:
There is a counterpart to this command, in which you can turn off the LED that aids in locating the physical
disk or expansion shelf. For more information, see
system --storage [--unblink] [--type <internal | external>] [--
service_tag>] [--disk <slot num>]
.
NOTE:
The above options are only available on a Physical DR.
Syntax
system --storage --blink --type external --service_tag HCM0PT3
Result
Turned on blinking for all disks in enclosure "HCM0PT3".
system --storage [--unblink] [--type <internal | external>] [--service_tag <service tag>] [--
disk <slot num>
Description
Turns off an LED that is used in locating a specific physical disk or data storage expansion shelf (using the
system --
storage
command) in the DR Series system. Select from the following DR Series system CLI command options:
--unblink
: turns off LED on the physical disk or expansion shelf.
--type <internal | external>
: identifies storage as an internal physical disk or external expansion shelf.
--service_tag <service tag>
: identifies physical disk or expansion shelf by its unique service tag.
--disk <slot num>
: identifies the disk slot number (if no disk slot is defined, it globally affects all disks).
93