Dell Force10 S60-44T Installing the S60 System - Page 32

Install a Fan Module, Grab Handle, Securing Screw, Fans and Filters, Fan Module1

Page 32 highlights

www.dell.com | support.dell.com Figure 5-1. The S60 Fan Module Securing Screw Fans and Filters PSU0 Grab Handle Fan Module1 Module slot 0 is on the left side of the system; module slot 1 is on the right side of the system. Install a Fan Module The fan modules in the S60 are field replaceable. The PSUs are in a single piece with the fans. For the procedure to replace the entire PSU, refer to Chapter 4, Power Supplies. To install a fan module, follow these steps: Step Task 1 Take the fan module out of the shipping box. 2 Use the grab handle to slide the fan module into the bay. 3 Tighten the securing screw at the top of the fan module. Replace a Fan Module Dell Force10 recommends replacing the fan tray within five minutes. If the fan tray is left out for too long, the system may experience traffic disruption. Error messages appear when the fan tray is removed and when the temperature approaches the threshold. • When a fan tray is removed, the system displays the following message: 00:00:37: %STKUNIT0-M:CP %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray 0 in unit 0 is missing or down • When the temperature reaches the maximum threshold (3), the system displays the following warning message: 00:00:38: %STKUNIT0-M:CP %CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! Unit 0 temperature is current temp; 32 | Fans and Filters

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

32
|
Fans and Filters
www.dell.com | support.dell.com
Figure 5-1.
The S60 Fan Module
Module slot 0 is on the left side of the system; module slot 1 is on the right side of the system.
Install a Fan Module
The fan modules in the S60 are field replaceable. The PSUs are in a single piece with the fans. For the
procedure to replace the entire PSU, refer to
Chapter
4, Power Supplies
.
To install a fan module, follow these steps:
Replace a Fan Module
Dell Force10 recommends replacing the fan tray within five minutes. If the fan tray is left out for too
long, the system may experience traffic disruption.
Error messages appear when the fan tray is removed and when the temperature approaches the threshold.
When a fan tray is removed, the system displays the following message:
00:00:37: %STKUNIT0-M:CP %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray 0 in unit 0
is missing or down
When the temperature reaches the maximum threshold (3), the system displays the following warning
message:
00:00:38: %STKUNIT0-M:CP %CHMGR-2-TEMP_SHUTDOWN_WARN: WARNING! Unit
0
temperature is current temp;
Step
Task
1
Take the fan module out of the shipping box.
2
Use the grab handle to slide the fan module into the bay.
3
Tighten the securing screw at the top of the fan module.
Grab Handle
Securing Screw
Fans and Filters
PSU0
Fan Module1