Denon AVR2307CI Owners Manual - English - Page 16
Error messages - reset
UPC - 081757507103
View all Denon AVR2307CI manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
ENGLISH Easy Setup Procedure Error messages • These error screens may be displayed when performing Auto Setup measurement and the automatic measurements can not be completed because of the speaker arrangement, measurement environment, or other factors. Please check the following matters, reset the pertinent items, and measure again. • When there is too much noise in the room, the speakers may not be detected properly. Should this happen, perform the measurements when the noise level is low, or switch off the power of the equipment that is producing the noise for the duration of the measurements. Press D H to select the items, then press F. Example Cause Measures q This screen will be displayed when the speakers required • Check that the pertinent speakers are properly connected. for producing suitable reproduction have not been detected. w This screen will be displayed when the speaker polarity is • Check the polarity of the pertinent speakers. For some connected in reverse. speakers, this screen may be displayed even though the speakers are properly connected. If so, select "Skip0". e This screen will be displayed when accurate measurements • Set up the speakers so that their position is farther away cannot be made due to the input level of the microphone being from the listening position. too high. • Lower the volume of the subwoofer speaker. r This screen will be displayed when the measurement • Connect the measurement microphone to the microphone microphone is not connected. connector. 13 ENGLISH Easy Setup Procedure