Epson Stylus COLOR 3000 Service Manual - Page 138
Repair of the C172 PSB/PSE Board at Component Level, Symptom, Condition, Cause, Checkpoint, Solution
View all Epson Stylus COLOR 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 138 highlights
Troubleshooting 5.3 Repair of the C172 PSB/PSE Board at Component Level This section contains information which enables you to repair and replace the components on the electrical board (C172 PSB/PSE). Table 5-5 lists the potential causes for each symptom in order of possibility, with which you are able to find and repair the defective part. Table 5-5. Component Repair of the C172 PSB/PSE Board Symptom Condition Cause The printer does not operate at all. +42 VDC is not output. Fuse (F1) is open. Transformer (T1) is open. Q1 is dead. Checkpoint Solution Check visually if the fuse is good. Replace the fuse F1. Check the transformer using a multimeter. Check the waveform at drain. Replace the transformer T1. Replace the Q1. Q2 or Q3 is dead. Waveform (1) Check the waveform at corrector. Replace the Q2 or Q3. PC1 is dead. Waveform (2) Check the voltage in lowering at Replace PC1. the Pin 5 or 7. Waveform (3) +5 VDC is L4962 is dead. Check the reference waveform Replace the L4962. not output. at the Pin 5. Waveform (4) Check the output waveform at the Pin 7. 5-10 Waveform (5) Rev. A