Symptom : CR does not operate normally., Symptom : The printer feeds paper abnormally., Condition
View all Epson Stylus COLOR 3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 140 highlights
Troubleshooting Table 5-7. Component Repair of the C211 MAIN Board (continued)) Condition Cause Checkpoint Solution Symptom : CR does not operate normally. CR motor does not rotate Sub gate array IC16 Check the waveform for the Replace the MAIN normally. is defective. signals HPASEA/B (Pin 7) output board or IC16. from the IC19/20. PF motor does not operate normally. CPU is defective. IC19 or IC20 is defective. CR motor is defective. Waveform (9) Replace the MAIN board. Check the the drive waveform Replace the IC19 or for the signals (Pin 10/15) IC20. output from the IC19/20. (See the waveform (9)) Check if the resistance of the Replace the CR motor. motor coil is as follows; 5Ω ± 7 % at 25°C per phase (Refer to Table 5-1.) Symptom : The printer feeds paper abnormally. Sub gate array IC6 is defective. Check the waveform for one of the following signals output from the IC17: PFA0/1 (Pin1/2) PFB0/1 (Pin 23/24) Replace the MAIN board. 5-12 CPU is defective. IC17 is defective. PF motor is defective. Waveform (10) Replace the MAIN board. Check the wavefoarms for one of Replace the MAIN the following signals output from board. the IC17: PFA0/1 (Pin 2/1) PFB0/1 (Pin 23/24) (Refer to the waveform (10).) Check if the resistance of the motor coil is as follows; 10Ω ± 10 % at 25 °C Replace the PF motor. (Refer to Table 5-1.) Rev. A