Fisher and Paykel RDV3-304-N Installation Guide - Page 15
Electrical connection
View all Fisher and Paykel RDV3-304-N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
ELECTRICAL CONNECTION All models IMPORTANT! z This range must be connected to the mains power supply only by a suitably qualified person. z This range must be earthed. z Always disconnect electric supply cord from the wall outlet or service disconnect before servicing this appliance. z Observe all governing codes and ordinances when grounding, in absence of which, observe National Electrical Code ANSI / NFPA No. 70. The rating label is located under the control panel Wiring diagrams are also in the service summary, attached to the inside of the toe kick panel A wiring diagram label is attached to the back of the range RDV3 models z A neutral supply wire must be provided from the power source (breaker panel) because critical range components, including the surface burner spark reignition module, require 120/240 VAC to operate safely and properly. z If the correct power supply circuit is not provided, it is the responsibility and obligation of the installer and user to have proper power supply connected. This must be accomplished in accordance with all applicable local codes and ordinances by a qualified electrician. It is the responsibility of the installer to ensure compliance of local codes. In the absence of local codes and ordinances, the power supply connection shall be in accordance with the National Electric Code. z Observe all governing codes and ordinances when grounding. In the absence of these codes or ordinances observe National Electrical Code ANSI/NFPA No. 70 current issue. See the following information in this section for grounding method.. z Range connection: P1-P2: 240V or 208V; P1-N: 120V; P2-N: 120V; 60Hz; Ground/ Earth required. IMPORTANT! z An improper 120/240 VAC power supply will cause malfunction, damage to this appliance, and possibly create a condition of shock hazard. z Improper connection of aluminium house wiring can result in a fire or shock hazard. Use only connectors designed and certified for connecting to aluminium wire. MODEL RDV3-304 RIV3-304 RDV3-366 RIV3-365 RDV3-488 RDV3-485GD RDV3-486GD RHV3-484 MAX. CURRENT DRAW 27 A 57 A 29 A 72 A 44 A 44 A 44 A 75 A CIRCUIT* FREQUENCY 30 A 50 A 30 A 50 A 50 A 50 A 50 A 50 A 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz *NEC Calculated Circuit Load, this is less than the total connected load listed on the rating label. IMPORTANT! The fourth prong (round grounding pin) should not, under any circumstances, be cut or removed. 15