Installation Instructions, LOCATION OF YOUR DRYER cont.
UPC - 084691079743
View all GE DPGT750GCPL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Installation Instructions LOCATION OF YOUR DRYER (cont.) REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION • Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back. • The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other surfaces is: 0" either side 3" front and rear • Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 52". • Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with the dryer (gas models only). BATHROOM OR BEDROOM INSTALLATION • The dryer MUST be vented to the outdoors. See EXHAUST INFORMATION. • The installation must conform with local codes or, in the absence of local codes, with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers) or NATIONAL FUEL GAS CODE, ANSI Z223 (for gas dryers). 20