Hayward CAT 6000 CAT 6000 Owners Manual - Page 43
Appendix C - Circulation Pump Interlock
View all Hayward CAT 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Appendix C - Circulation Pump Interlock The pump interlock is on pins 3 and 4 of the Pump Interface connector. Pins 3 and 4 should be connected to a dry set of contacts from the pump that are closed when the pump is running. The mating Conxall/Switchcraft connector kit P/N's are as follows depending on wire gauge and jacket O.D. of the cable being used: 6282-4PG-3DC 6282-4PG-311 6280-4PG-321 6282-4PG-513 Please note that before installing mating connector remove the factory installed jumper across pin 3 and 4 with a pair of needle nose pliers. See picture below. 42 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
42
Appendix C – Circulation Pump Interlock
The pump interlock is on pins 3 and 4 of the Pump Interface connector. Pins 3 and 4 should be con-
nected to a dry set of contacts from the pump that are closed when the pump is running.
The mating Conxall/Switchcraft connector kit P/N’s are as follows depending on wire gauge and jacket
O.D. of the cable being used:
6282-4PG-3DC
6282-4PG-311
6280-4PG-321
6282-4PG-513
Please note that before installing mating connector remove the factory installed jumper across pin 3