    Hayward ECOMMAND 4 Automation Operation Manual for models HPC-4 HPC-4-ACT HPC-4-RC HPC-4-ACT-RC www.haywardnet.com
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 2
    equipment, basic safety precautions should always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • ! WARNING: Disconnect all AC power during installation. • ! WARNING: Water in excess of 100 degrees Fahrenheit may be hazardous to your health. • ! WARNING: To reduce
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 3
    1 Automation 1 Manual System Operation Filter Pump 2 Lights and Aux Outputs 3 Pool/Spa Valves 3 Service 3 Automatic System Operation (Programming) Using the Programming Buttons 4 Programming Menu Flow Chart 5 Settings Menu 6 Timers Menu 10 Configuration Menu 13 Quick "How To" Guide
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 4
    Power Circuit Breaker Subpanel NOTE: This manual assumes that the ECOMMAND 4 has been wired and configured according to the Installation Manual. Aspects of the ECOMMAND 4 that pertain to system setup are not covered in this manual. Automation The ECOMMAND 4 can control up to 4 high voltage (120
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 5
    pump on manually at 8:00PM, it will run continuously until the next day at 5:00PM at which time it will turn off and follow the normal program from then on. Manually turning off a relay works in a similar fashion. Display Heater Indicator Valve 3 Indicator Check System Indicator Service Button
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 6
    manually, you can put the system into Service or Service-Timed mode by pressing the SERVICE button. Pressing the SERVICE button once will switch the system into service mode which means that all automatic functions are disabled, and the remote display/keypads are disabled (except for manual turn
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 7
    The ECOMMAND 4 controls most of your pool equipment automatically in order to minimize the time spent working on your pool. Most of the pool equipment can be programmed to operate on a timeclock basis. In addition, the desired pool and spa temperatures can be programmed. This section will guide you
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 8
    menu timers menu diagnostic menu configuration menu day and time water temperature air temperature chlorinator setting salt level reason pump is running (not scheduled) reason hi-speed is running (not scheduled) countdown time remaining heater control status system manual off check system error
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 9
    the Configuration menu are included in both the Operation and the Installation Manual. The "Diagnostic Menu" is primarily intended for the service technician and contains information and details about the system operation that are helpful in troubleshooting, if problems occur. Settings Menu The
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 10
    normal operation. If you manually turn off the filter pump (using the FILTER button on any display/keypad), the super chlorinate function terminates. When you turn the filter pump back on, super chlorinate will resume for the balance of the programmed number of hours. Spa Chlorinator 3% Adjust the
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 11
    Use this function to set the current day of the week and time. These values are used for all the automatic timeclock functions of the ECOMMAND 4 and are also displayed as part of the default menu. The ECOMMAND 4 is designed to keep the clock running during power outages lasting less than 7 days. If
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 12
    to previous/next menu item This menu will only appear if a wireless base station is connected to the ECOMMAND 4. Perform this procedure each time a wireless remote control is added to the ECOMMAND 4 system. During this procedure the wireless remote "learns" and remembers the ID code for the wireless
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 13
    timers which control the automatic operation of your pool/spa system. Each timeclock has a single on/off program per day. All of the timeclocks are setup (Configuration Menu) either as "all days" or "weekends/weekdays". If "weekends/weekdays" are selected, you will need to program on times for both
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 14
    start and stop times & to previous/next menu item Adjust time setting Move between start and stop times & to previous/next menu item This menu is only available if the system has been setup for "pool and spa". During the programmed spa time, the ECOMMAND 4 will turn on the filter pump and move the
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 15
    /next menu item This menu will appear only if the Aux1 is configured for countdown timer. This setting is the time after you manually turn on the Aux relay until the ECOMMAND 4 automatically turns off the relay. You can also manually turn off the relay at an earlier time by pressing the AUX1 button
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 16
    the ECOMMAND 4 will automatically detect and control any Aqua Rite/Swimpure(s) that is installed in the system. Display Allows for the display of salt (default) or mineral values. Pool/Spa Config. + to view/change Push to access Pool/Spa options Move to previous/next configuration menu Pool/Spa
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 17
    spa water will be filtered and sanitized. If "Pool Only" is selected, then the ECOMMAND 4 will switch the pool/spa valves to the "pool only" position at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on. This may be desirable on some systems
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 18
    freeze damage. If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold (see below), the ECOMMAND 4 will turn on the filter pump to circulate the water. If "Pool and Spa" is selected in the Pool/Spa sub-menu, the valves will also alternate between the pool and
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 19
    flashing and message on display). Pushing the filter button a second time will override the heater cooldown operation and turn the filter pump off. Heater Extend If "Enabled", the filter extend logic keeps the filter pump running beyond the normal turn-off time until the pool (or spa) is heated up
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 20
    relay will turn on when the LIGHTS button is pressed. The lights relay will turn off automatically after a programmed time (see Timers Menu in Operation Manual). The LIGHTS button can also be used to turn the output off. Low Speed of a 2-speed Filter Pump - the ECOMMAND 4 will turn on the lights
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 21
    desired pump speed Move to previous/next configuration menu ! WARNING: Do not use the ECOMMAND 4 to control an automatic pool cover. Swimmers may become entrapped underneath the cover. Aux1 Function Manual On/Off (default)-the aux relay will alternate between turning on and off when the aux button
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 22
    Timer - the aux relay will turn on when the AUX button is pressed and then will turn off automatically after a programmed time (see Timers Menu, Operation Manual). The AUX button can also be used to turn the output off. Low Speed of a 2-speed Filter Pump - the ECOMMAND 4 will operate the aux relay
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 23
    to previous/next configuration menu Valve3 Function Timeclock (default) - the valve turns on/off at the times set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running and solar heat is available and the water is less than
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 24
    day Toggle between 7-day (default) and Weekend/Weekday time options Move to previous/next configuration menu This selection affects ALL of the timeclock logic in the ECOMMAND 4. If "7-day" is selected, each timeclock will have one set of turn-on/turn-off settings that operate every day of the week
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 25
    the jet pump/blower is controlled by Aux1 or Aux2 (it should be marked on the label inside the door). Then press the appropriate button to turn on the jets/blower. Operate the Spa-Automatically 1. Press the "MENU" button repeatedly until "Timers Menu" is displayed. 2. Press the ">" button repeatedly
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 26
    operation can only be performed at the main ECOMMAND 4 unit. Both "Service" and "Service-Timed" disable all automatic programmed operations and allow manual operation from the main unit only. The buttons on the remote display/ keypads will still be able to turn equipment off in case of an emergency
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 27
    can put the system into Service or Service-Timed mode by pressing the "Service" button. Pressing the "SERVICE" button once will switch the system into service mode which means that all automatic functions are disabled, the optional remote display/keypads are disabled (except for manual turn off for
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 28
    first time, a second display will appear. Possible error messages are: • PCB Error • Low Salt/Amps/Minerals • High Salt/Amps/Minerals • Test Salt Level (Test Minerals) Refer to the Aqua Rite or Swimpure manual to correct error. Water Sensor Open circuit Air Sensor 94ºF Solar Sensor Short circuit
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 29
    26
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 30
    27
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 31
    the date of installation of the product. To obtain warranty service or repair, please contact the place of purchase or the nearest Goldline authorized warranty service center. For more information on authorized service centers please contact the Hayward/Goldline Technical Service Support Center ( 61
  • Hayward E-Command 4 | Model: ALL MODELS Operation - Page 32
    620 Division St. Elizabeth, NJ 07207 092420A Copyright © 2008 Goldine Controls
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

www.haywardnet.com
Hayward
ECOMMAND 4
Automation
Operation Manual
HPC-4
HPC-4-ACT
HPC-4-RC
HPC-4-ACT-RC
for models