HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 13

between the HP StorageWorks 1606 Extension SAN switches, Empty LAG creation

Page 13 highlights

Performance Data Aging tab has been removed from Server Management Console You cannot configure the Performance Data Aging settings in DCFM 10.1.4 or later. The tab has been removed from the Server Management Console (SMC). The default configuration settings are as follows: • 288 samples in a 5-minute period • 144 samples in a 30-minute period • 84 samples in a 2-hour period • 90 samples in a 1-day period • 606 total samples When migrating from an earlier release to DCFM 10.4.0, all historical data is truncated with respect to the default samples, and the aging configuration is not migrated. Encryption configuration has limited support The current commit limitation of a total of 25 LUN transactions (add, update, and remove) can cause delays in registering changes for LUN provisioning. To avoid this situation, HP recommends that you commit each transaction before making additional changes. IFL connection shown in topology after deleting all the VE-VEX tunnels present between the HP StorageWorks 1606 Extension SAN switches After deleting all the VE-VEX tunnels present between the 1606 Extension SAN switches, a rare instance has been seen where the IFL connection was still shown in topology. HP recommends that you unmonitor and monitor the switch again if this occurs. F_Ports connected to Access Gateway are not shown as attached ports under the switch If Access Gateway is connected to the switch, F_Ports connected to access gateway are not shown as attached virtual ports under the switch. HP recommends that you launch a new client. Empty LAG creation If a dot1x-enabled port is assigned to an LAG, an empty LAG is created. NOTE: If a two-port combination of dot1x-enabled and dot1x-disabled are added to an LAG, only the dot1x-disabled ports are added to the LAG. HP recommends that you verify the dot1x status on the port before assigning it to an LAG. Connection between the Access Gateway and switches does not appear when F_Port trunking is enabled on the Access Gateway If a switch configured with F_Port trunking is connected to the Access Gateway, the F_Port trunk group icon does not appear in the Product Tree, and the connection between the switch and the Access B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Performance Data Aging tab has been removed from Server Management
Console
You cannot configure the Performance Data Aging settings in DCFM 10.1.4 or later. The tab has
been removed from the Server Management Console (SMC). The default configuration settings are
as follows:
288 samples in a 5-minute period
144 samples in a 30-minute period
84 samples in a 2-hour period
90 samples in a 1-day period
606 total samples
When migrating from an earlier release to DCFM 10.4.0, all historical data is truncated with respect
to the default samples, and the aging configuration is not migrated.
Encryption configuration has limited support
The current commit limitation of a total of 25 LUN transactions (add, update, and remove) can cause
delays in registering changes for LUN provisioning. To avoid this situation, HP recommends that you
commit each transaction before making additional changes.
IFL connection shown in topology after deleting all the VE-VEX tunnels present
between the HP StorageWorks 1606 Extension SAN switches
After deleting all the VE-VEX tunnels present between the 1606 Extension SAN switches, a rare instance
has been seen where the IFL connection was still shown in topology. HP recommends that you unmonitor
and monitor the switch again if this occurs.
F_Ports connected to Access Gateway are not shown as attached ports under
the switch
If Access Gateway is connected to the switch, F_Ports connected to access gateway are not shown
as attached virtual ports under the switch. HP recommends that you launch a new client.
Empty LAG creation
If a dot1x-enabled port is assigned to an LAG, an empty LAG is created.
NOTE:
If a two-port combination of dot1x-enabled and dot1x-disabled are added to an LAG, only the
dot1x-disabled ports are added to the LAG.
HP recommends that you verify the dot1x status on the port before assigning it to an LAG.
Connection between the Access Gateway and switches does not appear when
F_Port trunking is enabled on the Access Gateway
If a switch configured with F_Port trunking is connected to the Access Gateway, the F_Port trunk group
icon does not appear in the Product Tree, and the connection between the switch and the Access
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional