Solution, Closed fixes summary, Trunking: CIM_ERR_NOT_FOUND Exception is displayed for
View all HP 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Closed fixes summary Solution Trunking: "CIM_ERR_NOT_FOUND" Exception is displayed for the following classes: Brocade_Trunk, Brocade_SwitchFCPortInTrunk, Brocade_NodeFCPortInTrunk,Brocade_TrunkInSwitch. User will get CIM_ERR_NOT_FOUND exception since Trunk-related classes were not implemented. Fixed in DCFM 10.4.0. FRU Indication is not received when user performs blade powered on/off for Fabric OS-based and M-EOS-based directors. Fixed in DCFM 10.4.0. Brocade_Chassis instance is not returned for switches that are in Unmanageable state. Fixed in DCFM 10.4.0. CIMOM server fails to start, leading to user not able to use the SMIAgent. Fixed in DCFM 10.4.0. Performance Management - Rx/Tx % Utilization is plotted incorrectly for xGE ports in Real Time Graph. Fixed in DCFM 10.4.0. Migration process (From installing DCFM 10.3.x to discovering all the switches) takes 35 minutes when migrating from DCFM 10.1.x with Fixed in DCFM 10.4.0. 13 Firmwares in repository and 3MB Zones files. PDCM: Configuration fails to load when switch username and password is changed. Fixed in DCFM 10.4.0. A seed switch converted into an Access Gateway does not become unmonitored when another switch in that fabric is discovered. This leads to other members of the fabric getting marked as missing; this fabric was allowed to be monitored using a different switch. Fixed in DCFM 10.4.0. Workaround prior to upgrade: Call Home: Call Home dialog box is blank after creating virtual switch Re-login to client. in Mi10k which is connected with two Fabric OS Virtual switches. Fixed in DCFM 10.4.0. Scalability: Connections are not shown properly in the topology for the Access Gateways. Fixed in DCFM 10.4.0. M-EOS discovery: Accept changes is not working for the pure EOS fabric, leading to user not being able to get the current status of the fabric. Fixed in DCFM 10.4.0. All fabrics no longer shown when switching to a one fabric view and then back to view all. Fixed in DCFM 10.4.0. LSAN Zoning; Activated LSAN zone is not shown in the LSAN Zoning dialog box after reopening the dialog box Workaround prior to upgrade: Wait for 15 to 30 minutes. Fixed in DCFM 10.4.0. Backend error is being displayed on creating a Profile/Map on the HP StorageWorks 2408 FCoE Converged Network switch or DC SAN Fixed in DCFM 10.4.0. Director Switch 10/24 FCoE blade. Unable to replicate the "All Configurations" from one 2408 FCoE switch to a different 2408 FCoE switch. Fixed in DCFM 10.4.0. 28