HP 1606 HP StorageWorks B-series Data Center Fabric Manager Enterprise, Profes - Page 35

Node Descriptor Flag is not updated in Port Connectivity View dialog, Two

Page 35 highlights

Closed fixes summary Solution "Second switch not compatible with first switch" error is given when we select the 4/256 Director with Multiprotocol Router blade as Switch Two, for the DC SAN Backbone Director with Multiprotocol Router blade, which already has "One Side" tunnel. Fixed in DCFM 10.4.0. Removing/Adding a TI Zone from DCFM should not affect the Active Zone configs in the switch, but currently disrupts traffic during TI zone config changes. Fixed in DCFM 10.4.0. Selective Ack is disabled by default when the Tunnel is created in DCFM , But in CLI, when a Tunnel is created, Selective Ack is enabled Fixed in DCFM 10.4.0. by default. In the Help content of Add FCIP Tunnel dialog box, information about Select Switch Two button is missing Fixed in DCFM 10.4.0. Configure Storage Encryption Fails When Target Info Entered Without ":", and user will not be able to create containers. Fixed in DCFM 10.4.0. FICON Emulation settings validation error message pops up in Transmission tab when there are no changes made in the FICON Emulation Fixed in DCFM 10.4.0. tab. Node Descriptor "Flag" is not updated in Port Connectivity View dialog box and Refresh operation also does not update the latest data from Fixed in DCFM 10.4.0. switch. Error message needs to be modified, which is shown when opening Add FCIP Circuit dialog box, if no FCIP license in the switch. Also error Fixed in DCFM 10.4.0. window title is not as per DCFM guideline. In host view, selecting a view that does not contain any fabric connected to the server, displays a blank view. Workaround prior to upgrade: The view will display the fabrics/hosts , if selected from the fabric view. Fixed in DCFM 10.4.0. Alias name is not getting displayed in the LSAN Zoning dialog box. Workaround prior to upgrade: User can see the alias name in Zoning dialog box. Fixed in DCFM 10.4.0. Circuit tab displays blank for the newly created single side tunnel Workaround prior to upgrade: Relaunch the FCIP Tunnel dialog box, the Circuit dialog box displays with appropriate data. Fixed in DCFM 10.4.0. Renaming a host reflects only after client re-launch. Workaround prior to upgrade: Restart the client. Fixed in DCFM 10.4.0. Error message is displayed and report is not generated while activating zone for a pure EOS fabric with report generation enabled. Fixed in DCFM 10.4.0. B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Solution
Closed fixes summary
Fixed in DCFM 10.4.0.
Second switch not compatible with first switch
error is given when
we select the 4/256 Director with Multiprotocol Router blade as Switch
Two, for the DC SAN Backbone Director with Multiprotocol Router
blade, which already has "One Side" tunnel.
Fixed in DCFM 10.4.0.
Removing/Adding a TI Zone from DCFM should not affect the Active
Zone configs in the switch, but currently disrupts traffic during TI zone
config changes.
Fixed in DCFM 10.4.0.
Selective Ack is disabled by default when the Tunnel is created in
DCFM , But in CLI, when a Tunnel is created, Selective Ack is enabled
by default.
Fixed in DCFM 10.4.0.
In the Help content of Add FCIP Tunnel dialog box, information about
Select Switch Two button is missing
Fixed in DCFM 10.4.0.
Configure Storage Encryption Fails When Target Info Entered Without
:", and user will not be able to create containers.
Fixed in DCFM 10.4.0.
FICON Emulation settings validation error message pops up in Trans-
mission tab when there are no changes made in the FICON Emulation
tab.
Fixed in DCFM 10.4.0.
Node Descriptor "Flag" is not updated in Port Connectivity View dialog
box and Refresh operation also does not update the latest data from
switch.
Fixed in DCFM 10.4.0.
Error message needs to be modified, which is shown when opening
Add FCIP Circuit dialog box, if no FCIP license in the switch. Also error
window title is not as per DCFM guideline.
Workaround prior to upgrade:
The
view will display the fabrics/hosts ,
if selected from the fabric view.
Fixed in DCFM 10.4.0.
In host view, selecting a view that does not contain any fabric connec-
ted to the server, displays a blank view.
Workaround prior to upgrade:
User
can see the alias name in Zoning
dialog box.
Fixed in DCFM 10.4.0.
Alias name is not getting displayed in the LSAN Zoning dialog box.
Workaround prior to upgrade:
Relaunch the FCIP Tunnel dialog box,
the Circuit dialog box displays with
appropriate data.
Fixed in DCFM 10.4.0.
Circuit tab displays blank for the newly created single side tunnel
Workaround prior to upgrade:
Restart
the client.
Fixed in DCFM 10.4.0.
Renaming a host reflects only after client re-launch.
Fixed in DCFM 10.4.0.
Error message is displayed and report is not generated while activating
zone for a pure EOS fabric with report generation enabled.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
35