HP 60 HP StorageWorks 60 Modular Smart Array Enclosure Maintenance and Service - Page 39
Specifications
View all HP 60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Specifications In this section Environmental specifications ...39 Storage enclosure specifications ...39 Environmental specifications Specification Temperature range Operating* Storage Relative humidity** Operating Storage Altitude ‡ Operating Non-operating Value 10°C to 35°C (50°F to 95°F) Maximum rate of change is 10º C/hr (18º F/hr) -30°C to 60°C (-22°F to 140°F) Maximum rate of change is 20º C/hr (36º F/hr) 10% to 90% relative humidity (Rh), 28º C (82.4º F) maximum wet bulb temperature, non-condensing 5% to 95% relative humidity (Rh), 38.7º C (101.66º F) maximum wet bulb temperature, non-condensing 3048 m (10,000 ft) This value may be limited by the type and number of options installed. 9144 m (30, 000 ft) * Temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. The upper limit may be limited by the type and number of options installed. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. ‡ Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Storage enclosure specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 8.8 cm (3.47 in) 59 cm (23.25 in) 44.80 cm (17.64 in) 24.6 kg (54 lb) 15.42 kg (34 lb) Specifications 39