Command Line Interface Table 4-8: Functionality Exclusive to the Command Line Interface continued Function Description Capability Exclusive to the Command Line Interface Enclosure Management Commands, continued REBOOT BAY } {FORCE} {[PXE | HDD | RBSU]} Sends a request to the server blade to perform a graceful shutdown. The server blade is then powered on. If no server blade is in the specified bay, the user is told that the bay is empty. Allows for optional boot argument The optional boot arguments require a BIOS version of 06/15/02 or greater of the ProLiant BL10e Server blade ROM. Adding an optional boot argument with force the blade to abandon the regular boot order and force a boot using the specified method. SET BAY BOOT FIRST [HDD | PXE] } Sets the IPL for each subsequent reboot. This setting is only valid for present blades and is cleared if a blade is removed. This command requires BIOS version 06/15/02 or greater for the ProLiant BL10e server blade ROM. Only enclosures and administrators may execute this command. SET BAY BOOT ONCE [HDD | PXE | RBSU] } Sets the boot device to be used on the next boot of the bay(s) specified. This setting is only valid on present blades and is cleared if the blade is removed. This command requires BIOS version 06/15/02 or greater for the ProLiant BL10e server blade ROM. Only enclosure and administrators may execute this command. continued 4-34 HP ProLiant BL e-Class Integrated Administrator User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Command Line Interface
Table 4-8:
Functionality Exclusive to the Command Line Interface
continued
Function
Description
Capability Exclusive to the
Command Line Interface
Enclosure Management Commands, continued
REBOOT BAY
<bay number>
{[ , | - ]
<bay number>}
{FORCE} {[PXE
| HDD | RBSU]}
Sends a request to the server blade
to perform a graceful shutdown.
The server blade is then powered
on. If no server blade is in the
specified bay, the user is told that
the bay is empty.
The optional boot arguments require
a BIOS version of 06/15/02 or
greater of the ProLiant BL10e Server
blade ROM.
Adding an optional boot argument
with force the blade to abandon the
regular boot order and force a boot
using the specified method.
Allows for optional boot argument
SET BAY BOOT
FIRST [HDD |
PXE] <bay
number> {[ , |
- ] <bay
number>}
Sets the IPL for each subsequent
reboot. This setting is only valid for
present blades and is cleared if a
blade is removed.
This command requires BIOS
version 06/15/02 or greater for the
ProLiant BL10e server blade ROM.
Only enclosures and
administrators may execute this
command.
SET BAY BOOT
ONCE [HDD |
PXE | RBSU]
<bay number>
{[ , | - ]
<bay number>}
Sets the boot device to be used on
the next boot of the bay(s) specified.
This setting is only valid on present
blades and is cleared if the blade is
removed.
This command requires BIOS
version 06/15/02 or greater for the
ProLiant BL10e server blade ROM.
Only enclosure and
administrators may execute this
command.