HP BL10e HP ProLiant BL e-Class Integrated Administrator User Guide - Page 163

Enter the appropriate commands, SHOW ENCLOSURE STATUS

Page 163 highlights

Performing Common Administrative Tasks 2. Enter the appropriate commands: SHOW ENCLOSURE FAN [ | ALL] IMPORTANT: This command displays the status, redundancy, partner, speed, and part number for one or all fans in the enclosure. SHOW ENCLOSURE INFO IMPORTANT: This command displays the enclosure name, type, part number, serial number, and asset tag number; the Integrated Administrator software and hardware version; the MAC address of the Integrated Administrator, and the interconnect tray type, part number, and serial number. SHOW ENCLOSURE POWERSUPPLY [ | ALL] IMPORTANT: This command displays the status, AC input status, capacity, input voltage range #1 (Volts), input voltage range #2 (Volts), input frequency range (Hz), part number, serial number, and hardware revision for one or both power supplies in the enclosure. SHOW ENCLOSURE STATUS IMPORTANT: This command displays the status of enclosure health, Integrated Administrator health, and the Unit Identification LED under the heading "enclosure status," and displays the status and capacity of the power supplies of the enclosure under the heading "power status." SHOW ENCLOSURE TEMP IMPORTANT: This command displays the location, status (OK, warm, degraded, or failed), and temperature (degrees Fahrenheit or Celsius) for all the temperature sensors of the enclosure. HP ProLiant BL e-Class Integrated Administrator User Guide 6-21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228

Performing Common Administrative Tasks
2.
Enter the appropriate commands:
SHOW ENCLOSURE FAN [<fan number> | ALL]
IMPORTANT:
This command displays the status, redundancy, partner, speed, and part
number for one or all fans in the enclosure.
SHOW ENCLOSURE INFO
IMPORTANT:
This command displays the enclosure name, type, part number, serial
number, and asset tag number; the Integrated Administrator software and hardware
version; the MAC address of the Integrated Administrator, and the interconnect tray type,
part number, and serial number.
SHOW ENCLOSURE POWERSUPPLY [<power supply number> | ALL]
IMPORTANT:
This command displays the status, AC input status, capacity, input voltage
range #1 (Volts), input voltage range #2 (Volts), input frequency range (Hz), part number,
serial number, and hardware revision for one or both power supplies in the enclosure.
SHOW ENCLOSURE STATUS
IMPORTANT:
This command displays the status of enclosure health, Integrated
Administrator health, and the Unit Identification LED under the heading “enclosure status,”
and displays the status and capacity of the power supplies of the enclosure under the
heading “power status.”
SHOW ENCLOSURE TEMP
IMPORTANT:
This command displays the location, status (OK, warm, degraded, or
failed), and temperature (degrees Fahrenheit or Celsius) for all the temperature sensors of
the enclosure.
HP ProLiant BL e-Class Integrated Administrator User Guide
6-21