HP Cisco MDS 9216 Cisco MDS 9000 Family System Messages Reference (OL-15956-01 - Page 333
SCSI target-3, show flash, vsan_get_global_value, process cpu, show system internal sysmgr service all
View all HP Cisco MDS 9216 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 333 highlights
Chapter 2 System Messages and Recovery Procedures for the Cisco MDS 9000 Family Send documentation comments to [email protected] Error Message SCSI target-2-PSS_INIT_FAIL: pss initialization failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) initialization failed due to the error listed. No SCSI discovery can be performed. Recommended Action Enter the show flash command or use a similar Fabric Manager/Device manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 2.0(1b). SCSI target-3 Error Message SCSI target-3-PROC_VSAN_GET_RATOV_FAIL: Failed to get vsan attribute RATOV from VSAN Manager, error: [hex]. Explanation SCSI target process used the vsan_get_global_value() API for RATOV and it failed because of the error listed. Recommended Action This is a non-fatal error. The default value for RATOV is used. Enter the show process cpu and show system internal sysmgr service all commands or use a similar Fabric Manager/Device Manager procedure to collect more information. See the VSAN Manager system error codes for the reason. Introduced Cisco MDS SAN-OS Release 2.0(1b). Error Message SCSI target-3-PSS_CREATE_FAIL: pss create runtime database failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) had a create runtime database failure because of the error listed. No SCSI discovery can be performed. Recommended Action Enter the show flash command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 2.0(1b). Error Message SCSI target-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed due to error: [hex]. Explanation SCSI target process persistent storage service (PSS) delete runtime entry key failed because of the error shown in the error message. Recommended Action Enter the show flash command or use a similar Fabric Manager/Device Manager procedure to collect more information. See PSS system error codes for the reason. Introduced Cisco MDS SAN-OS Release 2.0(1b). OL-15956-01 Cisco MDS 9000 Family System Messages Reference 2-297