HP Dc7100 Troubleshooting Guide - Page 39
Start > All Programs >, Accessories > System Tools >, Character Map, Problem, Cause
UPC - 829160356877
View all HP Dc7100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Troubleshooting Without Diagnostics Solving Display Problems (Continued) Problem Cause Fuzzy focus; streaking, ghosting, or shadowing effects; horizontal scrolling lines; faint vertical bars; or unable to center the picture on the screen. (flat panel monitors using an analog VGA input connection only) Flat panel monitor's internal digital conversion circuits may be unable to correctly interpret the output synchronization of the graphics card. Certain typed symbols do not appear correct. Graphics card is not seated properly or is bad. The font you are using does not support that particular symbol. Solution 1. Select the monitor's Auto-Adjustment option in the monitor's on-screen display menu. 2. Manually synchronize the Clock and Clock Phase on-screen display functions. To download a SoftPaq that will assist you with the synchronization, go to the following Web site, select the appropriate monitor, and download either SP20930 or SP22333: www.hp.com/support 1. Reseat the graphics card. 2. Replace the graphics card. Use the Character Map to locate the and select the appropriate symbol. Click Start > All Programs > Accessories > System Tools > Character Map. You can copy the symbol from the Character Map into a document. 2-24 www.hp.com Troubleshooting Guide