Error occurs when starting the HPPP service on RHEL IA64, Invalid IP address
View all HP Pro UPS 500 240V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 128 highlights
Action: 1. Navigate to /etc and open the file named host with a text editor. 2. Update the information in the file to reflect updated IP address, Email, and User information. For example: 172.25.234.200, [email protected], root 3. Reboot the computer. Error occurs when starting the HPPP service on RHEL IA64 Symptom: When installing HPPP on RHEL IA64 the following error message appears on the terminal: Unable to init module 'bin/musb.so' (libunwind.so.7 cannot open shared object file: No such file or directory) Possible cause: The RHEL IA64 operating system installation is missing the following dependency: Libunwind-0.98.5-5.el5.ia64.rpm Action: 1. Insert the Redhat operating system CD or DVD into the DVD-ROM drive. 2. Locate and then install the library: libunwind-0.98.5-5.el5.ia64.rpm. 3. Install HPPP. Invalid IP address Possible Cause: IP addresses are not checked for validity. Action: Verify that the IP address entered is valid. Links in emails do not work correctly for Linux Action: Update the /etc/hosts file with the correct host name or IP address. Low battery warning is displayed Action: Plug the UPS into an AC grounded outlet for at least 24 hours to charge the batteries, and then test the batteries. Replace the batteries if necessary. No power Action: Verify that the UPS is connected to a working outlet and that the UPS is powered up. Troubleshooting 128