HP Pro UPS 500 240V HP Power Protector User Guide - Page 87

Notified Applications, Communication Loss

Page 87 highlights

Notified Applications Click a column header to sort the Notified Applications list. To customize the columns, select Columns, and then select the checkboxes that correspond to the data you want to include. Available column options include: • Type-An icon indicating the application type • Status-An icon indicating the current status of the communication between the Administrator and the Client ( Normal or Communication Loss) • IP address-The IP address of the application • Name-The name of the associated HPPP Client • Description-A description of the application • Version-The version of the application • Runtime to empty-The remaining runtime of the power source in the case of a power failure • Shutdown initiated after-The amount of time that elapses between a power failure and the initiation of the shutdown sequence This value is configured in the HPPP Client and displays in this column. • Estimated runtime to shutdown-The amount of runtime available before the associated HPPP Client shutdown sequence initiates This value is configured in the HPPP Client and displays in this column. • OS shutdown time-The amount of time required to shut down the operating system • Shutdown diagram-A chronological illustration of the shutdown sequence for the associated HPPP Client The diagrams present a visual representation of the shutdown sequencing between the different agents. o The total width of the diagram represents the remaining runtime of the power source in the case of a power failure. o The green area represents the amount of runtime available before the agent shutdown sequence initiates. o The orange area represents the amount of time required to shut down the agent. o The red area represents the amount of time the agent is powered off. • Power source shutoff-Indicates if the load segment is configured to shut off after HPPP Clients shut down during a power failure • Power source-The name of the UPS powering the device • Load segment-The associated UPS load segment • User type-A user-defined value that can be used to sort devices The user type can be specified by editing a device on the Device Discovery screen (on page 50). • User note-A user-defined message that can be used to sort devices A user note can be entered by editing a device on the Device Discovery screen (on page 50). • Access-The status of the HPPP Client's login credentials to the HPPP Administrator (must be an administrator level user name and password) Configuration and operation 87

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

Configuration and operation 87
Notified Applications
Click a column header to sort the Notified Applications list. To customize the columns, select
Columns
, and
then select the checkboxes that correspond to the data you want to include. Available column options
include:
Type
—An icon indicating the application type
Status
—An icon indicating the current status of the communication between the Administrator and the
Client (
Normal or
Communication Loss)
IP address
—The IP address of the application
Name
—The name of the associated HPPP Client
Description
—A description of the application
Version
—The version of the application
Runtime to empty
—The remaining runtime of the power source in the case of a power failure
Shutdown initiated after
—The amount of time that elapses between a power failure and the initiation of
the shutdown sequence
This value is configured in the HPPP Client and displays in this column.
Estimated runtime to shutdown
—The amount of runtime available before the associated HPPP Client
shutdown sequence initiates
This value is configured in the HPPP Client and displays in this column.
OS shutdown time
—The amount of time required to shut down the operating system
Shutdown diagram
—A chronological illustration of the shutdown sequence for the associated HPPP
Client
The diagrams present a visual representation of the shutdown sequencing between the different agents.
o
The total width of the diagram represents the remaining runtime of the power source in the case of
a power failure.
o
The green area represents the amount of runtime available before the agent shutdown sequence
initiates.
o
The orange area represents the amount of time required to shut down the agent.
o
The red area represents the amount of time the agent is powered off.
Power source shutoff
—Indicates if the load segment is configured to shut off after HPPP Clients shut
down during a power failure
Power source
—The name of the UPS powering the device
Load segment
—The associated UPS load segment
User type
—A user-defined value that can be used to sort devices
The user type can be specified by editing a device on the Device Discovery screen (on page
50
).
User note
—A user-defined message that can be used to sort devices
A user note can be entered by editing a device on the Device Discovery screen (on page
50
).
Access
—The status of the HPPP Client’s login credentials to the HPPP Administrator (must be an
administrator level user name and password)