HP Pro UPS 500 240V HP Power Protector User Guide - Page 79

Statistics panel, Reconfiguring an HPPP power source

Page 79 highlights

Statistics panel This panel displays a list of calculated statistics. Statistics are calculated over the specified time period for the following categories: • Estimated power consumption-The estimated amount of power consumed • Average apparent power-The average apparent power • Power lost count-The number of utility power failures that have occurred • Cumulative power lost time-The total amount of time utility power has been out • UPS overload-The number of times the UPS has detected an overload condition To configure the range of time over which statistics are calculated: 1. Click the icon. The Days interval screen appears. 2. Enter the beginning date in the From field, or click the icon to select the date from a calendar. 3. Enter the ending date in the To field, or click the icon to select the date from a calendar. 4. Click Save. The configured interval displays at the top of the panel. The beginning date displays in the bottom-left corner. The ending date displays in the bottom-right corner. 5. Click the time date and time values in the bottom left and right corners to shift the displayed time windows back or forward, respectively. To download a .csv file of the statistical data, click the icon. Reconfiguring an HPPP power source If an HPPP Administrator power source needs to be changed, the following requirements must apply: • The HPPP Administrator was previously configured to a power source. • One or more HPPP Clients are currently connected to the HPPP Administrator. Configuration and operation 79

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137

Configuration and operation 79
Statistics panel
This panel displays a list of calculated statistics.
Statistics are calculated over the specified time period for the following categories:
Estimated power consumption
—The estimated amount of power consumed
Average apparent power
—The average apparent power
Power lost count
—The number of utility power failures that have occurred
Cumulative power lost time
—The total amount of time utility power has been out
UPS overload
—The number of times the UPS has detected an overload condition
To configure the range of time over which statistics are calculated:
1.
Click the
icon. The Days interval screen appears.
2.
Enter the beginning date in the From field, or click the
icon to select the date from a calendar.
3.
Enter the ending date in the To field, or click the
icon to select the date from a calendar.
4.
Click
Save
. The configured interval displays at the top of the panel. The beginning date displays in the
bottom-left corner. The ending date displays in the bottom-right corner.
5.
Click the time date and time values in the bottom left and right corners to shift the displayed time
windows back or forward, respectively.
To download a .csv file of the statistical data, click the
icon.
Reconfiguring an HPPP power source
If an HPPP Administrator power source needs to be changed, the following requirements must apply:
The HPPP Administrator was previously configured to a power source.
One or more HPPP Clients are currently connected to the HPPP Administrator.