HP ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance an - Page 68
Disk Operation., Virtual Mode
View all HP ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1703-SCSI None Incorrect cabling. cable error detected. Internal SCSI cable not attached to system board connector. System halted. 1704- None System attempted to Unsupported Virtual Mode perform a virtual mode disk operation Disk Operation. without virtual mode DOS Driver memory services. Required. System halted. 1705-Locked None SCSI bus failure. SCSI Bus Detected. System halted. 1730-Fixed Disk None Fixed disk drive error. 0 does not support DMA Mode. 1731-Fixed Disk None Fixed disk drive error. 1 does not support DMA Mode. 1740-Fixed Disk None Fixed disk drive error. 0 failed Set Block Mode command 1741-Fixed Disk None Fixed disk drive error. 1 failed Set Block Mode command Action Ensure that the integrated SCSI controller has SCSI termination attached. Use fixed-disk device driver that supports virtual mode memory services. Run Diagnostics. Replace failed assembly as indicated. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct.