HP ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance an - Page 81
Array - Drives
View all HP ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
3-27 POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1797-Drive None Hard parity error while Array - Array reading data from Accelerator posted writes Read Error memory. Occurred. Data in Array Accelerator has been lost. Array Accelerator is disabled. 1798-Drive None Hard parity error while Array - Array writing data to posted Accelerator writes memory. Write Error Occurred. Array Accelerator is disabled. 1799-Drive None Volume failed due to Array - Drive(s) loss of data in posted- Disabled due writes memory. to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re- enable logical drives. Beeps only: 2 2L, 2S Power is cycled. Long + 2 Short Temperature too hot. Processor fan not installed or spinning. Action Enable Array Accelerator. Enable Array Accelerator. Press F1 to continue with logical drives disabled or F2 to accept data loss and re-enable logical drive. Check fans. Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide