HP ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance an - Page 74
Array Drive, Physical Drive
View all HP ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
3-20 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1777-Drive None Cooling fan failure, Array External internal temperature Drive alert or open side Subsystem Error panel. 1778-Drive None This message appears Array resuming whenever a controller Automatic reset or power cycle Data Recovery occurs while process Automatic Data Recovery is in progress. 1779-Drive None Intermittent drive Array failure and/or possible Controller detects loss of data. replacement drives 1780-Disk 0 Failure None 1781-Disk 1 Failure None 1782-Disk Controller Failure 1784-Drive Array Drive Failure, Physical Drive 1785-Drive Array not Configured None None None Hard drive/format error. Hard drive/format error. Hard disk drive circuitry error. Defective drive and/or cables. Configuration error. Action Inspect for cooling fan failure or open side panel. No action necessary. If this message appears and drive X has not been replaced, this indicates an intermittent drive failure. This message also appears once immediately following drive replacement whenever data must be restored from backup. Run Diagnostics. Replace failed assembly as indicated. Run Diagnostics. Replace failed assembly as indicated. Run Diagnostics. Replace failed assembly as indicated. Check for loose cables. Replace defective drive X and/or cable(s). Run the System Configuration Utility and correct. Continued