HP StorageWorks 4000 Compaq StorageWorks Fibre Channel Troubleshooting Guide - Page 21
Replacing the RA4000 Controller without RA4000 Redundant Controller, Squeeze the latches
View all HP StorageWorks 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Introduction 1-13 Replacing the RA4000 Controller without RA4000 Redundant Controller When an RA4000 Controller fails in an online RA4000 Array: 1. Perform a normal system shutdown of the servers. 2. Power down the RA4000. 3. Unplug all power cords from the RA4000 Array. Remove the Fibre Channel cable attached to the GBIC in the failed RA4000 Controller. 4. Squeeze the tabs on either side of the GBIC , then remove the GBIC by pulling it straight out of the RA4000 Controller . 2 3 1 2 Figure 1-11. Removing the Fibre Channel cable and GBIC 5. Squeeze the latches and pivot open the two ejector levers securing the RA4000 Controller. 6. Remove the RA4000 Controller by pulling it straight out of the chassis . 1 1 2 3 Figure 1-12. Removing the RA4000 Controller