HP StorageWorks 4000 Compaq StorageWorks Fibre Channel Troubleshooting Guide - Page 50

Visual and Physical Inspection of the FC_AL

Page 50 highlights

4-10 Compaq StorgeWorks Fibre Channel Troubleshooting Guide Visual and Physical Inspection of the FC_AL Begin Check the seating of all GBICs and cable connectors on the FC-AL. Has the problem with the FC- Yes AL been corrected? No Remove each GBIC and check visually for any defects. Replace GBICs and make sure each GBIC is snapped fully into the connector. The GBIC is keyed to fit only one way. D Done

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

4-10
Compaq StorgeWorks Fibre Channel Troubleshooting Guide
Visual and Physical Inspection of the FC_AL
D
Yes
No
Check the seating of all GBICs
and cable connectors on the
FC-AL.
Begin
Remove each GBIC and check
visually for any defects.
Replace GBICs and make sure
each GBIC is snapped fully into
the connector.
The GBIC is
keyed to fit only one way.
Has the problem with the FC-
AL been corrected?
Done