HP StorageWorks 4000 Compaq StorageWorks Fibre Channel Troubleshooting Guide - Page 49
the Fibre Channel Host Bus, Storage Hub 7? See Appendix A.
View all HP StorageWorks 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
StorageWorks RAID Array 4000 and 4100 Troubleshooting Flow Charts 4-9 C1 Are the active LEDs lit on the No Is the GBIC seated properly in No Storage Hub 7? See Appendix A. the receptacle? Reset the GBIC. Yes Are any Bypass LEDs lit on the Storage Hub 7 that have GBICs and cables installed? See Appendix A. Yes Verify that power is applied to all devices on the loop. Return Yes Replace the GBIC. if the problem persists replace the storage Hub 7. No Did the utility program respond with an ALPA? Yes A device on the loop is causing the entire loop to become unstable. Unplug all Fibre Channel Array Controllers from the loop except one. Run the Utility program again. If the No Fibre Channel Array Controller appears, plug in another Fibre Channel Array Controller and run the utility program again. If no Fibre Channel Array Controllers appear, the Fibre Channel Host Bus Adapter in the server may be at fault. Is the Active LED blinking on all Fibre Channel Array Controllers? See Appendix A. Yes Reset the Fibre Channel Array Controller and run the utility program again. No Possible Fibre Array problem. Check seating of the Fibre Channel Array Controller. Ckeck to make sure the power supply is secure and the power source is active.