HP Surestore L10 Service and User Manual (Short- and Long-Wave) - Page 56

Procedure 6: Set Manufacturing Values

Page 56 highlights

3. From the Main menu, enter 2 (Set Networking parameters) to display the Network Setup menu. Network Setup Menu: 1. Return to Main Menu 2. Select IP address [current = nnn.nnn.nnn.nnn] 3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn] 4. Select Default Gateway address [current = nnn.nnn.nnn.nnn] 5. Save Network Setup changes and reboot 6. Proxy Master Setup 4. Enter 6 to display the Proxy Master menu: Proxy Master Menu: 1. Return to previous Menu 2. Toggle current Proxy Master state and reboot 5. Enter 2 to change the Proxy Master setting to ENABLED and reboot the hub. When the Main menu appears, verify the new Hub Controller version. Procedure 6: Set Manufacturing Values After resetting the hub and verifying the new firmware versions, set the system.sysDescr and system.sysObjectID values. 1. From the Main menu, enter mfg to display the Manufacturing Settings Menu. Manufacturing Settings Menu: 1. Return to Main Menu 2. Set sysdescr [current = ] 3. Set system OID [current = 1.3.6.1.4.1] 4. Toggle port bypass persistence mode [current = Enabled] > 2. Enter 2 to display the Set sysDescr string Menu. Set sysDescr string Menu: [current = ] 1. Return to Manufacturing Settings Menu or enter new sysDescr string > 54 Updating the Hub Firmware

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

54
Updating the Hub Firmware
3.
From the Main menu, enter
2
(Set Networking parameters) to display the Network
Setup menu.
Network Setup Menu:
1. Return to Main Menu
2. Select IP address [current = nnn.nnn.nnn.nnn]
3. Select Subnetworking Mask [current = nnn.nnn.nnn.nnn]
4. Select Default Gateway address [current = nnn.nnn.nnn.nnn]
5. Save Network Setup changes and reboot
6. Proxy Master Setup
4.
Enter
6
to display the Proxy Master menu:
Proxy Master Menu: <Current state: Proxy Master DISABLED>
1. Return to previous Menu
2. Toggle current Proxy Master state and reboot
5.
Enter
2
to change the Proxy Master setting to
ENABLED
and reboot the hub. When the
Main menu appears, verify the new Hub Controller version.
Procedure 6: Set Manufacturing Values
After resetting the hub and verifying the new firmware versions, set the
system.sysDescr
and
system.sysObjectID
values.
1.
From the Main menu, enter
mfg
to display the Manufacturing Settings Menu.
Manufacturing Settings Menu:
1. Return to Main Menu
2. Set sysdescr [current = ]
3. Set system OID [current = 1.3.6.1.4.1]
4. Toggle port bypass persistence mode [current = Enabled]
>
2.
Enter
2
to display the Set sysDescr string Menu.
Set sysDescr string Menu: [current = ]
1. Return to Manufacturing Settings Menu
or enter new sysDescr string
>