Honeywell HJZTP User Manual - Page 51
Ptz Control Functions When Using Honeywell Maxpro, Mode Kd6/hd6 Protocol
View all Honeywell HJZTP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
SECTION 8: PTZ CONTROL FUNCTIONS WHEN USING HONEYWELL MAXPRO MODE (KD6/HD6) PROTOCOL 8.1 INTRODUCTION This section provides information on controlling and programming the HD6I/KD6I set for Maxpro Mode protocol. 8.2 RESET KD6i/HD6i The KD6i/HD6i must be reset through the setup menu. Send the HD6i to PreShot 90 to access the setup menus, then access the diagnostics menu, then select the Reset Scan and Camera option. Refer to Section 7.15. 8.3 CONTROLLING SCAN ASSEMBLIES The lens iris is automatically controlled by the camera, but can be controlled manually from a controller. The camera lens auto exposure mode can be enabled or disabled using the controller. PreShot 92 toggles the unit between auto and manual exposure. A message "AUTO EXPOSURE ON" or "AUTO EXPOSURE OFF" is displayed on the video when the scan executes PreShot 92. Auto lens exposure control is the factory default for scans set for Maxpro mode. If the KD6/HD6 has a day/night camera with an IR block filter it can be controlled manually through the setup menus or by sending the scan to a preprogrammed PreShot reserved for the NightShot mode. PreShot 94 is reserved for Maxpro 8.4 FREEZE / UNFREEZE VIDEO The freeze/unfreeze video function described in Section 7.10 can be invoked using PreShot 95. 8.5 FLASHBACK OPERATION The flashback function described in Section 7.11 can be invoked using PreShot 96. Rev. 1.01 41 900.0570 8-Sept-05