Hour Meter, Tracking Knob, Drive forward at full throttle with both motion

Page 20 highlights

CONTROLS Hour Meter The hour meter displays the total operating time. It will flash CHG OIL (Change Oil) at 50 hour intervals. The flash duration is one hour before and one hour after the interval. The CHG OIL icon will come on and shut off automatically. The hour meter cannot be manually reset. Tracking Knob If the mower is not tracking straight, check the air pressure in both rear tires. Recommended air pressure for the rear tires is 15 psi (1 bar). 1. Tracking adjustments are made using the tracking bolt and tracking knob. The tracking bolt and tracking knob act as limiting devices for the motion control levers when in the full-forward position. 2. For preliminary tracking adjustment, move unit to an open, unobstructed area such as an empty parking lot or open field. 3. Back the tracking bolt out until flush with nut. 4. Loosen tracking knob out until flush with nut. 5. Test operate unit by driving it at full throttle and the full forward position on both motion control levers. Gradually turn in the tracking bolt on the right hand side until the unit noticeably starts drifting right. 6. Drive forward at full throttle with both motion control levers in the full forward position. Gradually turn in the tracking knob (left side) until unit tracks straight. Hour meter Tracking adjustment 8065-084 8065-086 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

ContRols
20
Tracking Knob
If the mower is not tracking straight, check the
air pressure in both rear tires. Recommended air
pressure for the rear tires is 15 psi (1 bar).
Tracking adjustments are made using the tracking
1.
bolt and tracking knob. The tracking bolt and
tracking knob act as limiting devices for the
motion control levers when in the full-forward
position.
For preliminary tracking adjustment, move unit
2.
to an open, unobstructed area such as an empty
parking lot or open field.
Back the tracking bolt out until flush with nut.
3.
Loosen tracking knob out until flush with nut.
4.
Test operate unit by driving it at full throttle and
5.
the full forward position on both motion control
levers. Gradually turn in the tracking bolt on the
right hand side until the unit noticeably starts
drifting right.
Drive forward at full throttle with both motion
6.
control levers in the full forward position.
Gradually turn in the tracking knob (left side) until
unit tracks straight.
Hour Meter
The hour meter displays the total operating time.
It will flash CHG OIL (Change Oil) at 50 hour intervals.
The flash duration is one hour before and one hour
after the interval. The CHG OIL icon will come on
and shut off automatically. The hour meter cannot be
manually reset.
8065-084
Hour meter
8065-086
Tracking adjustment