Fuses, Choke Control, Cutting Height Pedal, A, Primary fuse.
View all Husqvarna P-ZT6126 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
CONTROLS Fuses Fuses are located on the right hand side of the machine. They are accessed by tilting the seat forward. Fuses are flat pin fuses type as used in automobiles. There are three fuses with ratings and functions: 1. 20 A, Primary fuse. 2. 7.5 A, Mower deck coupling. 3. 10 A, Accessories Choke Control The choke control is used for cold starts to provide the engine with a richer fuel mixture. For cold starts the control should be pulled out to its extent. Fuses Cutting Height Pedal The cutting height pedal lifts the deck to allow setting the desired deck height. For transport, push the lift pedal fully forward until the deck lift latches in the transport (highest) position. Choke control Cut height lift pedal 23 8065-043 8065-085 8065-087