IBM 84903bu User Manual - Page 31

Installation

Page 31 highlights

v Check the instructions that come with the drive to see whether you have to set any switches or jumpers on the drive. If you are installing a SAS device, be sure to set the SAS ID for that device. v Diskette drives, tape drives, CD drives, CD-RW drives, and DVD/CD-RW combo drives are examples of removable-media drives. You can install removable-media drives in bays 1, 2, and 3 only. v To install a 3.5-in. drive in a 5.25-in. bay, you must use the 5.25-in. conversion kit. v Only a 3.5-in. device can be installed in bay 3. v The server supports only one diskette drive. v The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all bays and PCI, PCI Express, and PCI-X slots covered or occupied. When you install a drive or PCI, PCI Express, or PCI-X adapter, save the EMC shield and filler panel from the bay or the PCI, PCI Express, or PCI-X adapter slot cover in the event that you later remove the option. v For a complete list of supported options for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. Installing a drive in bay 2 or 3 EMC shield Filler panel Drive retainer clip To install a drive in bay 2 or 3, complete the following steps: 1. Read the safety information that begins on page v and "Installation guidelines" on page 7. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables. 3. Remove the side cover (see "Removing the side cover" on page 10). 4. Remove the two-piece bezel (see "Removing the two-piece bezel" on page 11). Chapter 2. Installing options 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

v
Check
the
instructions
that
come
with
the
drive
to
see
whether
you
have
to
set
any
switches
or
jumpers
on
the
drive.
If
you
are
installing
a
SAS
device,
be
sure
to
set
the
SAS
ID
for
that
device.
v
Diskette
drives,
tape
drives,
CD
drives,
CD-RW
drives,
and
DVD/CD-RW
combo
drives
are
examples
of
removable-media
drives.
You
can
install
removable-media
drives
in
bays
1,
2,
and
3
only.
v
To
install
a
3.5-in.
drive
in
a
5.25-in.
bay,
you
must
use
the
5.25-in.
conversion
kit.
v
Only
a
3.5-in.
device
can
be
installed
in
bay
3.
v
The
server
supports
only
one
diskette
drive.
v
The
electromagnetic
interference
(EMI)
integrity
and
cooling
of
the
server
are
protected
by
having
all
bays
and
PCI,
PCI
Express,
and
PCI-X
slots
covered
or
occupied.
When
you
install
a
drive
or
PCI,
PCI
Express,
or
PCI-X
adapter,
save
the
EMC
shield
and
filler
panel
from
the
bay
or
the
PCI,
PCI
Express,
or
PCI-X
adapter
slot
cover
in
the
event
that
you
later
remove
the
option.
v
For
a
complete
list
of
supported
options
for
the
server,
see
servers/eserver/serverproven/compat/us/.
Installing
a
drive
in
bay
2
or
3
EMC shield
Filler panel
Drive retainer clip
To
install
a
drive
in
bay
2
or
3,
complete
the
following
steps:
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
7.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables.
3.
Remove
the
side
cover
(see
“Removing
the
side
cover”
on
page
10).
4.
Remove
the
two-piece
bezel
(see
“Removing
the
two-piece
bezel”
on
page
11).
Chapter
2.
Installing
options
17