Icom ID-880H Instruction Manual - Page 146
Busy lockout, Time-out timer, Auto repeater
View all Icom ID-880H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 146 highlights
10 MENU SCREEN OPERATION D Busy lockout Turns the busy lockout function ON or OFF. This function inhibits transmission while receiving a signal or when the squelch is open. (default: OFF) D Time-out timer To prevent accidental prolonged transmission, etc., the trans- ceiver has a time-out timer. This function cuts transmission OFF after 1, 3, 5, 10, 15 or 30 min. of continuous transmis- sion. This timer can be cancelled. • OFF : The time-out timer is turned OFF. (default) • 1 to 30 MIN : The transmission is cut OFF after the set period elapses. D Auto repeater USA/CHN/EXP/KOR versions only The auto repeater function automatically turns ON or OFF the duplex operation and tone encoder. The offset and repeater tone settings are not changed by the auto repeater function. Reset these frequencies, if necessary. USA/CHN/EXP versions: • OFF : The auto repeater function is turned OFF. • RPT1 : Activates for duplex only. (default) • RPT2 : Activates for duplex and tone. KOR version: • OFF : Deactivates the function. • ON : Activates duplex and tone. (default) 128