Icom ID-880H Instruction Manual - Page 51

Current repeater call sign programming

Page 51 highlights

DV MODE PROGRAMMING 4 t Repeat the step r to enter the desired station call sign. • Up to an 8 digit call sign can be set. • If an unwanted character is entered, push [ ](LOW) or [ ](CS) to select the character, then push [CLR](DR) to erase the selected character, or push and hold [CLR](DR) for 1 sec. to erase all characters following the cursor. y Push [ ](MONI) to store the programmed call sign and return to UR call sign screen. u Push [MENU ] to return to frequency indication.  For your information The ID-880H has a call sign edit record function. When editing a call sign stored in a call sign memory (or regular memory/call channel), the default setting is to store the edited call sign into a blank channel automatically. (When all call sign memories are already programmed, the edited call sign will overwrite the selected channels call sign.) The programmed call sign can be over-written when the setting of "EDIT R" (Edit record) is set to OFF or SEL. (p. 135) However, you must manually over-write a reprogrammed call sign in regular memory/call channels (temporary operation without over-writing is possible). D Current repeater call sign programming 1 "RPT1" or "RPT2" can store current call sign only, and repeater call signs must be stored in the repeater list (p. 34). 2 3 q Enter "RPT1" or "RPT2" in call sign screen. MENU ¶ CALL-S ¶ RPT1 or RPT2 4 (Push [MENU ]), (rotate [DIAL], then push [ ](MONI).) 5 • RPT1/RPT2 call sign screen is displayed. 6 7 8 9 10 w Push [ ](LOW) to enter call sign programming mode. 11 • The 1st digit blinks. e Rotate [DIAL] to select the desired character or code. 12 • Push [ ](LOW) or [ ](CS) to move the cursor right or left, re- 13 spectively. r Repeat the step e to enter the desired repeater call sign. 14 • Call sign can be up to 8 digits long. 15 • If an unwanted character is entered, push [ ](LOW) or [ ](CS) to select the character, then push [CLR](DR) to erase the se- 16 lected character, or push and hold [CLR](DR) for 1 sec. to erase all characters following the cursor. 17 t Push [ ](MONI) to store the programmed call sign and 18 returns to call sign screen. y Push [MENU ] to return to frequency indication. 19 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

33
4
DV MODE PROGRAMMING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
t
Repeat the step
r
to enter the desired station call sign.
• Up to an 8 digit call sign can be set.
If an unwanted character is entered, push
[
µ
]
(LOW) or
[
´
]
(CS)
to select the character, then push
[CLR]
(DR) to erase the se-
lected character, or push and hold
[CLR]
(DR) for 1 sec. to erase
all characters following the cursor.
y
Push
[
]
(MONI) to store the programmed call sign and
return to UR call sign screen.
u
Push
[MENU
]
to return to frequency indication.
For your information
The ID-880H has a call sign edit record function.
When editing a call sign stored in a call sign memory (or reg-
ular memory/call channel), the default setting is to store the
edited call sign into a blank channel automatically. (When all
call sign memories are already programmed, the edited call
sign will overwrite the selected channels call sign.)
The programmed call sign can be over-written when the set-
ting of “EDIT R” (Edit record) is set to OFF or SEL.
(p. 135)
However, you must manually over-write a reprogrammed call
sign in regular memory/call channels (temporary operation
without over-writing is possible).
D
Current repeater call sign programming
“RPT1” or “RPT2” can store current call sign only, and re-
peater call signs must be stored in the repeater list
(p. 34)
.
q
Enter “RPT1” or “RPT2” in call sign screen.
MENU
CALL-S
RPT1 or RPT2
(Push
[MENU
]
), (rotate
[DIAL]
, then push
[
]
(MONI).)
• RPT1/RPT2 call sign screen is displayed.
w
Push
[
µ
]
(LOW) to enter call sign programming mode.
• The 1st digit blinks.
e
Rotate
[DIAL]
to select the desired character or code.
Push
[
µ
]
(LOW) or
[
´
]
(CS) to move the cursor right or left, re-
spectively.
r
Repeat the step
e
to enter the desired repeater call sign.
• Call sign can be up to 8 digits long.
If an unwanted character is entered, push
[
µ
]
(LOW) or
[
´
]
(CS)
to select the character, then push
[CLR]
(DR) to erase the se-
lected character, or push and hold
[CLR]
(DR) for 1 sec. to erase
all characters following the cursor.
t
Push
[
]
(MONI) to store the programmed call sign and
returns to call sign screen.
y
Push
[MENU
]
to return to frequency indication.