Page 6 highlights
5 Installing Filtration System a Brass Nut Screws provided are for use in wood Ferrule studs or cabinets only. Use wall anchors (not supplied) for installation into drywall. M ark hole locations for filter Phlaesaticd and bracket in a spot that allotuwbes for filter replacement. D rill 1/8" starter holes and attach bracket to wall with wood screws, turning until snug. Personal Injury: Do not locate filter above an outlet or other electrical device. Install head and bracket so that connections require no stretching, kinking or pinching of tubing. R emove red filter cap, insert filter cartridge into filter head and twist clockwise until "LOCK" arrow on the filter aligns with arrow on bracket. 6 Brass Insert Final Water Connection a BBrraassss NNuutt FeFrerurlreule Brass Insert Plastic tube Brass Nut Ferrule Property Damage: Join remaining tube to cold water supply only. Install a T-fitting (not included) onto the cold water supply line. Install dedicated water control valve with 3/8" compression fitting. A t the end of the white 3/8" tube from the filter or quick-connector, slide the supplied brass nut and ferrule over the tube and then push in the brass tube insert. Insert the white 3/8" tube into the 3/8" compression fitting and tighten. b T urn on the water supply. Depress the dispenser's HOT handle and hold it until water flows from the spout (approximately 1 to 2 minutes). b from wa2ter supply line 1 to dispenser Property Damage: Tube runs need to form to the cabinet's contours to allow storage space with no sharp bends. Tubes need clean, perpendicular, burr-free cuts to ensure a true fit. D etermine length of tubing required, then cut to length making sure the cut is p2erpendicular and burr-free. Insert a white 3/8" tube into inlet side of filter head until it stops. Press in again to ensure a secure fit. Insert the other white 3/8" tube into outlet side of filter head until it stops. Press in again to ensure a secure fit. 3 c HC1100, HC2200, GN1100, GN2200, GN2215, HC2215 HC3300, H3300 3 From filter or water supply line Plug From filter or water supply line Property Damage: Do not extend the lines farther than the 16" provided. Ensure tube(s) and "Y" connector are securely fit. Insert the copper tubes(s) from the dispenser into "Y" quick-connector using the plug for hot-only models. C onnect the white 3/8" tube from the right outlet on the filter head into the quick-connect fitting until it stops. Press in again to ensure a secure fit. To remove tube(s) or plug from quick-connector, depress the release ring and gently pull away. Scalding Hazard: The faucet dispenses near-boiling (212ºF) water which can instantly cause scalds or burns. Use care when operating this appliance. R un the water for at least 2 minutes to flush lines (both the hot and cold handles independently if applicable). Note: See box below for special instructions on operation of InDulge™ Modern faucets. Dispensing Hot Water Dispensing Cool Water (HC3300, H3300) (HC3300) Brass Nut Ferrule Brass Insert Plastic tube Brass Nut Ferrule Scalding Hazard: The faucet dispenses near-boiling (212ºF) water which can instantly cause scalds or burns. Use care when operating this appliance. Operating Instructions for InDulgeTM Modern Faucets Featuring OptiPush™ hot side activation with automatic shut off and cool side Stay-On™, which keeps the faucet open when dispensing cool water. H C3300: To dispense instant hot water, first press down on the faucet handle and then push the handle backward in the direction of the red indicator on the top of the handle. To dispense cool water, first press down on the faucet handle and then pull the handle forward in the direction of the blue indicator on the handle. Featuring OptiPush™ hot side activation with automatic shut off. H 3300: To dispense instant hot water, first press down on the faucet handle and then push the handle backward in the direction of the red indicator on the top of the handle. d Discharge tube 1 2 T o redirect filter replacement water discharge, place 6" clear tube over vent hole on the left side of filter head. From water supply line To dispenser It is normal for approximately 2 oz. of water to discharge when filter is removed. 3 N ote: 3/8" fitting is required to make connection to water supply. C onnect remaining white 3/8" tube to incoming water supply line. (See Step 6.) c Property Damage: A standard grounded outlet within 30" of the dispenser is required under the sink. Do not use an extension cord set with the dispenser. C heck all connections to ensure they are tight and that there are no leaks. P lug in instant hot water tank. Water will be cold at first. Allow 12-15 minutes for water to reach target temperature. Gurgling or hissing is normal during the initial heating cycle. If the water coming from the faucet is not hot 15 minutes after the unit has been plugged in - or for other issues related to the operation of your instant hot water dispenser - refer to the "Troubleshooting" section on Page 16. 10 11