JVC C11U Instruction Manual - Page 29
Alarm 1, Motion Detection, Relay Alarm, Retry [1 to 3], Alarm force output, Out port setting
UPC - 046838325670
View all JVC C11U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
2-4 Other Settings with V.Networks Setup Tool [2. Alarm Setting] (continued) 1 Alarm 1 Select [ON] to convert signals input to the [ALARM INPUT 1] terminal to [Alarm 1] signals. 5 Retry [1 to 3] This function sets how many times an alarm alert to [V.Networks Controller] is repeated (1 to 3). If [Alarm Output] is selected, alarm signals are sent to the [ALARM OUTPUT] terminal according to the output port setting. 2 Alarm 2 Select [ON] to convert signals input to the [ALARM INPUT 2] terminal to [Alarm 2] signals. If [Alarm Output] is selected, alarm signals are sent to the [ALARM OUTPUT] terminal according to the output port setting. 3 Motion Detection Select [ON] for motion within the set area to be recognized as a cause for an alarm. If [Alarm Output] is selected, alarm signals are sent to the [ALARM OUTPUT] terminal according to the output port setting. 4 Relay Alarm Select here to enable the alarm function, which is activated when two alarms are successively received within a certain period of time. The sequence and interval of alarm input can be set. If [Alarm Output] is selected, alarm signals are sent to the [ALARM OUTPUT] terminal according to the output port setting. Note Note Depending on the LAN environment, alarm alert might fail. If it fails, set the value to "3". In such a case, alarm by [V.Networks Controller] itself is set off only once. 6 Alarm force output If [Output] is pressed, alarm signals are sent to the [ALARM OUTPUT] terminal. This forced output is used for checking the alarm function. 7 Out port setting Enable this function to output alarm signals to the [ALARM OUTPUT] terminal. Using output values, set the polarity, high or low, and output time (1 to 5000 ms) according to the equipment connected. If initialization is set to start, the set alarm signal is output once when the power is turned on. 8 List Press here to show the IP addresses of the PCs to which alarm input is reported. To delete an IP address, select the address and press [Delete]. • A second alarm input enables this relay alarm function, and alarm will not be activated for this second input. • Unless the alarm output is enabled, this function is not activated even if [Alarm Output] of the [Alarm Settings] screen is selected. Note • If more than 10 destinations are set, this function is not activated. 29