JVC C11U Instruction Manual - Page 52
Message, Recording, Alarm Operation, Relay Alarm, Playing wave file, Execute application file
UPC - 046838325670
View all JVC C11U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Operations (Step 4 Setting with V.Networks Controller) 4-7 Alarm Setting (continued) 1 Message When an alarm is received, the message entered into the text box is displayed. The maximum number of characters that can be entered is 100. 2 Recording When an alarm is received, recording starts. Non-Stop : Recording continues until the Stop button is pressed. Stop 1min : Recording stops after 1 minute. 3 Playing wave file When an alarm is received, a specified Wave file is replayed. Press the [Browse] button to specify a Wave file. Note If a large Wave file (.wav) is selected, the alarm operation may become slow depending on the PC performance. Note • The [Stop 1min] mode is for conserving the hard disk space. • In this mode, recording stops after 1 minute even if recording has already started before the alarm input. 4 Execute application file When an alarm is received, a specified program is executed. Press the [Browse] button to specify a program. Note Alarm Operation The following settings are required for the operation of the alarm that has been set. 1. [Alarm Reg] is enabled in the [Setting] menu of the [V.Networks Controller.] (☞ Page 45) 2. Each alarm setting in [Alarm Setting] of [V.Networks Setup Tool] is enabled. (☞ Page 28) Relay Alarm When the relay alarm function is enabled, subsequent alarms will not be activated. 52