Kenmore 3243 Installation Instructions - Page 5

Typical, Under, Counter, Installation, of an Electric, Built-in, Oven with, a Cooktop, Mounted, - gas cooktop

Page 5 highlights

Typical Under Counter Installation of an Electric Built-in Oven with a Cooktop Mounted Above All mounting hardware must be used to secure the builtqn oven to tile cabinets. Refer to the builtqn oven installation instructions. Junction box must be located approx. 3" to the left of the builtqn oven cutout, This cooktop may be installed over certain builtqn elee tric oven models. Side filler panels are necessary to isolate the unit from adjoining cabinets. Panel height should allow for installation of approved cooktop models. See "Typical Gas Cooktop Installation Over an Electric Builtqn Oven Installed Under the Counter" on previous page. 32" Min.** (81.3 cm) 36" (91.4 cm) 208/240 Volt grounded junction box for built-in Use 3/4" (1.9 cm) plywood, installed on two runners, flush with toe plate. Must be capable of supporting 150 Ibs. Cut an opening in wood base minimum 9" (22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from left side filler panel, to route armoured (.able to junction box. 4 1/2" (11.4 cm) Max.* * If no cooktop is installed directly over the oven unit, S" (12.7 cm) maximum is allowed. ** 32" (81.3 cm) min. from top of cabinet to top of runners must be maintained. OVEN SIZE 30" (76,2cm) 27" (68,6crn) CUTOUT DIMENSIONS (inches) Min 27¼" (69,2cm) E Max, 28s/_" - (727cm) Min 281/2" (72,4cm) F Max, 29" - (737cm) 27¼" (69,2crn) 28s/_" - (727cm) 24V8" (63,1cm) 25¼" (641cm) G 23Y2" (59,7cm) 23Y2" (59,7cm)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Typical
Under
Counter
Installation
of an Electric
Built-in
Oven with
a Cooktop
Mounted
Above
All mounting
hardware
must be used to secure
the builtqn oven to tile
cabinets.
Refer to
the
builtqn
oven
installa-
tion instructions.
Junction box must
be located approx.
3" to the left of
the builtqn oven
cutout,
208/240 Volt grounded junction
box for built-in
This cooktop may
be installed over
certain builtqn elee
tric oven models.
Side filler panels are necessary to
isolate the unit from adjoining
cabinets.
Panel height should allow
for installation of approved cooktop
models.
See "Typical Gas Cooktop
Installation Over an Electric Builtqn
Oven Installed Under the Counter"
on previous page.
32" Min.**
(81.3 cm)
36"
(91.4 cm)
Use 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting
150 Ibs.
Cut
an opening in wood base minimum 9"
(22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from
left side filler panel, to route armoured
(.able to junction
box.
4 1/2" (11.4 cm)
Max.*
*
If no cooktop is installed directly
over the oven unit, S" (12.7 cm)
maximum is allowed.
** 32"
(81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
CUTOUT
DIMENSIONS
(inches)
OVEN
SIZE
E
F
G
Min
Max,
Min
Max,
30"
27¼"
28s/_"
281/2"
29"
23Y2"
(76,2cm)
(69,2cm)
-
(727cm)
(72,4cm)
-
(737cm)
(59,7cm)
27"
27¼"
28s/_"
24V8"
25¼"
23Y2"
(68,6crn)
(69,2crn)
-
(727cm)
(63,1cm)
(641cm)
(59,7cm)