Kenmore 3243 Installation Instructions - Page 9

Valve Stem, Hookups, Complete, Model, Serial, Number, Location, Before, Call for, Service - sears

Page 9 highlights

2. Turn on EJectricat Power and Open Main Shutoff Gas Valve 3_ Check the igniters Operation of electric: igniters should be checked after cooktop and supply line connectors have been carefully checked for leaks and the cooktop has been connected to electric power. To operate the surface burner: A. Push in and turn a surface burner knob to the LITE position. You will hear a small ticking noise; this is the sound of the electric, ignitor which lights the burner. B. After the burner lights, turn to the desired flame size. The controls do not have to be set at a particular mark. Use the marks as a guide and adjust the flame as needed. 4_ Adjust the "LO"' or "SIMMER" Setting of Surface Burner Valves (see Figure 9) Push in and turn each control knob to tile "LO" (or "SIMMER") setting. The"LO" setting of each burner has been set at the factory to the lowest setting available to provide reliable reignition of the burner. If it does not stay lit on the"LO" setting, check the setting as follows. _Be operation. careful when performing this A. Allow cooktop to cool to room temperature. B. Light all burners by turning each control knob to LITE until burners ignite, and then set them at "HI". C. _turn the knob of the burner you want to adjust to tile LOWEST POSITION. D. If burner goes out, readjust valve as follows: Remove the surface burner control knob, insert a thin-bladed screw driver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased with the turn of the screw. To increase flame size turn the screw counterclockwise and to decrease turn clockwise. Adjust flame until you can quickly turn knob from HI to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out. E. If you need to adjust another burner, repeat the steps from A to D above until all burners operate properly. Hollow Valve Stem_ Figure 9 When All Hookups are Complete Make sure all controls are left in the OFF position. Make sure the flow of combustion and ventilation air to the cooktop is unobstructed. Model and Serial Number Location The serial plate is located on the underside of the cooktop. When ordering parts for or making inquires about your range, always be sure to include the model and serial numbers and a lot number or letter from the serial plate of your cooktop. Your serial plate also tells you the rating of the burners, the type of fuel and the pressure the cooktop was adjusted for when it left the factory. Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Refer to your Use and Care Guide for Sears service phone numbers, or call 1-800-4-MY-HOMI:®.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

2.
Turn
on EJectricat Power
and Open
Main
Shutoff
Gas Valve
3_
4_
Check the igniters
Operation
of electric: igniters should be checked after
cooktop
and supply line connectors
have been
carefully
checked for leaks and the cooktop
has
been connected to electric
power.
To operate
the surface
burner:
A.
Push in and turn
a surface burner knob to the
LITE position.
You will
hear a small ticking
noise;
this is the sound of the electric, ignitor
which
lights the burner.
B.
After the burner lights, turn to the desired flame
size. The controls
do not have to be set at a
particular
mark.
Use the marks as a guide and
adjust the flame as needed.
Adjust
the "LO"' or "SIMMER"
Setting
of Surface
Burner
Valves
(see Figure
9)
Push in and turn each control
knob to tile
"LO" (or
"SIMMER")
setting.
The"LO"
setting of each
burner has been set at the factory to the lowest
setting available to provide reliable reignition
of the
burner.
If it does not stay lit on the"LO"
setting,
check the setting as follows.
_Be
careful when performing
this
operation.
A.
Allow
cooktop to cool to room temperature.
B.
Light all burners by turning
each control
knob to
LITEuntil
burners ignite,
and then set them at
"HI".
C.
_turn
the knob of the burner you want to
adjust to tile
LOWEST POSITION.
D.
If burner goes out, readjust valve as follows:
Remove the surface burner control
knob, insert a
thin-bladed
screw driver into the hollow
valve
stem and engage the slotted screw inside. Flame
size can be increased or decreased with the turn
of the screw. To increase flame
size turn
the
screw counterclockwise
and to decrease turn
clockwise.
Adjust flame
until you can quickly
turn knob from HI to LOWEST POSITION without
extinguishing
the flame.
Flame should be as
small as possible without
going out.
E.
If you need to adjust another burner, repeat the
steps from A to D above until all burners operate
properly.
Hollow
Valve Stem_
Figure
9
When
All
Hookups
are
Complete
Make sure all controls are left in the OFF position.
Make sure the flow of combustion
and ventilation
air to
the cooktop is unobstructed.
Model
and
Serial
Number
Location
The serial plate is located on the underside of the
cooktop.
When ordering
parts for or making inquires about your
range, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
of
your
cooktop.
Your serial plate also tells you the rating of the burners,
the type of fuel and the pressure the cooktop
was
adjusted for when it left the factory.
Before
You
Call for
Service
Read the Before You Call for Service Checklist
and
operating
instructions
in your Use and Care Guide.
It
may save you time and expense. The list includes
common
occurrences that are not the result of defective
workmanship
or materials in this appliance.
Refer to your Use and
Care Guide
for Sears service
phone numbers, or call 1-800-4-MY-HOMI:®.