KitchenAid KUID508HPS Installation Instructions - Page 3
Electrical Requirements
View all KitchenAid KUID508HPS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Model Identification: Standard model Standard Model Utilities Custom panel model ■■ Custom Panel ice maker models have been designed for flush install in instances where the power supply, water supply, and drain are located in adjacent cabinetry. ■■ For installation of product with utilities behind the ice maker, flush install may not be achieved. ■■ Refer "Custom Panel Model Utilities" illustration and table below it for utility slot/hole cutout location. Electrical Requirements WARNING 34" (86.4 cm) Min. 34¹⁄2" (87.6 cm) Max. 11¹⁄2" (29.2 cm) 3¹⁄2" 9" (8.9 cm)(22.9 cm) 24" (60.96 cm) A 28¹⁄2" (72.4 cm) B A. Recommended location for electrical and plumbing fixtures B. Floor level Custom Panel Model Utilities Required zone for utility hole/slot cutout location A B C D 71/2" (19.05 cm) 71/2" (19.05 cm) Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. Before you move your ice maker into its final location, it is important to make sure you have the proper electrical connection: A 115 V, 60 Hz, AC only, 15 or 20 A electrical supply, properly grounded in accordance with the National Electrical Code and local codes and ordinances, is required. It is recommended that a separate circuit, serving only your ice maker, be provided. Use a receptacle which cannot be turned off by a switch or pull chain. IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) equipped outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Ice quality may be affected. If nuisance tripping has occurred, and if the condition of the ice appears poor, dispose of it. Recommended Grounding Method The ice maker must be grounded. The ice maker is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, 3 prong, grounding-type wall receptacle, grounded in accordance with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is not available, it is the personal responsibility of the customer to have a properly grounded, 3 prong wall receptacle installed by a qualified electrician. Utility Slot/Cutout Location Zone A Dimension B C Diameter of the hole D 9" (22.9 cm) 8" (20.3 cm) 7" (17.8 cm) 2" (5 cm) 3