Konica Minolta bizhub PRESS C71hc bizhub PRESS C1060/C1070/C1070P/PRO C1060L D - Page 76
On the [Calibration Manager] screen
View all Konica Minolta bizhub PRESS C71hc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
19 On the [Calibration Manager] screen, click [Accuracy Measurement] under [3. G7 Calibration]. 20 Click [Print]. Print the color chart that is to be measured using the instrument. 21 Click [Start]. 22 Measure the chart using the instrument. After you finish the chart measurement, click [OK]. NOTICE When the values of 'Ch and 'E* are not G7 standard as the result of the accuracy check, the dialogue is displayed. You can choose to recalculate and register the calibration table to fit in the target range or register as is in the dialogue. Conduct the recalculation. If you recalculate and the values of 'Ch and 'E* are still not G7 standard, check the following adjustment items. - Gamma automatic adjustment - Density balance adjustment - Maximum Density Auto Adjustment (RU) - Color density manual control 3-44