Konica Minolta bizhub PRESS C71hc bizhub PRESS C1070/C1070P/C1060/C71hc/bizhub - Page 95

Executing calibration using the image controller, EFI Spectrometer ES-1000, Fiery Command WorkStation

Page 95 highlights

bizhub PRESS C1070/C1070P/C1060/C71hc bizhub PRO C1060L Executing calibration using the image controller This section describes how to carry out calibration for daily maintenance using Fiery Command WorkStation and a colorimeter (EFI Spectrometer ES-1000). Tips This section describes how to carry out calibration when using coated paper as an example. " Use a USB cable to connect EFI Spectrometer ES-1000 to your computer. For information about EFI Spectrometer ES-1000 setting and adjustment, refer to the manual supplied with this machine. # Start Fiery Command WorkStation. For information about how to start this application, refer to page 3-17. $ Click [Job Center] - [Calibrate] in sequence. Calibrator starts. % Select the printing preferences for calibration. - Calibrate: Coated - Paper source: Paper tray with coated paper loaded - Measurement method: EFI ES-1000 NOTICE NOTICE This section describes how to specify a printing environment when using coated paper as an example. Specify a printing environment according to the paper and tray actually used. 5 5-36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

5-36
bizhub PRO C1060L
bizhub PRESS C1070/C1070P/C1060/C71hc
5
Executing calibration using the image controller
This section describes how to carry out calibration for daily maintenance using
Fiery Command WorkStation
and a
colorimeter (
EFI Spectrometer ES-1000
).
Tips
This section describes how to carry out calibration when using coated paper as an example.
A
Use a USB cable to connect
EFI Spectrometer ES-1000
to your computer.
For information about
EFI Spectrometer ES-1000
setting and adjustment, refer to the manual supplied
with this machine.
B
Start
Fiery Command WorkStation
.
For information about how to start this application, refer to page 3-17.
C
Click [Job Center] - [Calibrate] in
sequence.
Calibrator starts.
D
Select the printing preferences for
calibration.
-
Calibrate: Coated
-
Paper source: Paper tray with coated paper
loaded
-
Measurement method: EFI ES-1000
NOTICE
NOTICE
This section describes how to specify a printing
environment when using coated paper as an example.
Specify a printing environment according to the paper
and tray actually used.