Konica Minolta bizhub PRESS C71hc bizhub PRESS C1070/C1070P/C1060/C71hc/bizhub - Page 98

Specifying the reference image quality, With Relay Unit RU

Page 98 highlights

5.2 Image Quality Adjustment Specifying the reference image quality To stabilize the image quality of this machine, specify the reference values (targets) of the entire printing system in advance. If you change the setting value in [Custom Screen], hue variations may be drastically changed. If you change the screen, specify the standard image quality following the procedure to avoid hue variations. Tips If the image quality has not been appropriately adjusted only through daily calibration, you may improve the situation by carrying out the following tasks. Order STEP1 STEP2 STEP3 STEP4 Menu item Without Relay Unit With Relay Unit RU- RU-509 509 Screen Pattern (Refer to the HTML User's Guide.) [Gamma Automatic Adj.] (Refer to the HTML User's Guide.) [Printer Gamma Sensor Adjustment] (Refer to the HTML User's Guide.) [Density Balance Adjustment] (Refer to the HTML User's Guide.) [Printer Gamma Offset Adjustment] (Refer to the HTML User's Guide.) [Color Density Control] (page 5-31) Description Select the screen to be used with the screen setting (assignment) changed. Automatically adjusts the color reproducibility of all the output paper. [Printer Gamma Sensor Adjustment]: Adjusts the IDC sensor using the scanner. [Density Balance Adjustment]: Automatically corrects the density balance. [Printer Gamma Offset Adjustment]: Changes the printer gamma curve, and adjusts the gradation of the highlighted part and the background optical density. STEP5 [Density Balance Adjustment] (Refer to the HTML User's Guide.) Calibration (page 5-31) STEP6 Calibration - (page 5-31) [Color Density Control]: Select [Basic Setting], then set [Periodical Adj. Execution] to [ON]. If necessary, execute [Color Density Manual Control]. [Density Balance Adjustment]: Automatically corrects the density balance. Calibration: Calibrates the color reproducibility that fluctuates from day to day. Calibrates the color reproducibility that fluctuates from day to day. Carry out the adjustment continuously in sequence. If you have interrupted the adjustment during processing, execute "STEP2. Gamma Automatic Adj." before restarting the adjustment. For example, if you have interrupted the adjustment at the end of "STEP3. Density Balance Adjustment (with the Relay Unit RU-509 installed)", execute "STEP2. Gamma Automatic Adj." when restarting the adjustment, then execute "STEP4. Color Density Control". If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order. For details about the setting procedure, refer to the HTML User's Guide. 5-39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

5-39
5.2
Image Quality Adjustment
Specifying the reference image quality
To stabilize the image quality of this machine, specify the reference values (targets) of the entire printing system in
advance.
If you change the setting value in [Custom Screen], hue variations may be drastically changed. If you change the
screen, specify the standard image quality following the procedure to avoid hue variations.
Tips
If the image quality has not been appropriately adjusted only through daily calibration, you may improve the situation
by carrying out the following tasks.
Carry out the adjustment continuously in sequence. If you have interrupted the adjustment during processing, execute
"STEP2. Gamma Automatic Adj." before restarting the adjustment. For example, if you have interrupted the adjustment
at the end of "STEP3. Density Balance Adjustment (with the
Relay Unit RU-509
installed)", execute "STEP2. Gamma
Automatic Adj." when restarting the adjustment, then execute "STEP4. Color Density Control".
If sufficient adjustment results are not obtained via daily maintenance, also carry out the adjustment in this order.
For details about the setting procedure, refer to the
HTML User's Guide
.
Order
Menu item
Description
Without Relay Unit
RU-509
With Relay Unit RU-
509
STEP1
Screen Pattern (Refer to the
HTML User's
Guide
.)
Select the screen to be used with the screen set-
ting (assignment) changed.
STEP2
[Gamma Automatic Adj.] (Refer to the
HTML
User's Guide
.)
Automatically adjusts the color reproducibility of
all the output paper.
STEP3
[Printer Gamma
Sensor Adjustment]
(Refer to the
HTML
User's Guide
.)
[Density Balance Ad-
justment]
(Refer to the
HTML
User's Guide
.)
[Printer Gamma Sensor Adjustment]:
Adjusts the IDC sensor using the scanner.
[Density Balance Adjustment]:
Automatically corrects the density balance.
STEP4
[Printer Gamma Off-
set Adjustment]
(Refer to the
HTML
User's Guide
.)
[Color Density Con-
trol]
(page 5-31)
[Printer Gamma Offset Adjustment]:
Changes the printer gamma curve, and adjusts
the gradation of the highlighted part and the
background optical density.
[Color Density Control]:
Select [Basic Setting], then set [Periodical Adj.
Execution] to [ON]. If necessary, execute [Color
Density Manual Control].
STEP5
[Density Balance
Adjustment]
(Refer to the
HTML
User's Guide
.)
Calibration
(page 5-31)
[Density Balance Adjustment]:
Automatically corrects the density balance.
Calibration:
Calibrates the color reproducibility that fluctuates
from day to day.
STEP6
Calibration
(page 5-31)
-
Calibrates the color reproducibility that fluctuates
from day to day.