LG 50PW450 Service Manual - Page 12

CI+ Key Download - dtv

Page 12 highlights

11-2. Signal TABLE CMD : A0h LENGTH : 85~94h (1~16 bytes) ADH : EEPROM Sub Address high (00~1F) ADL : EEPROM Sub Address low (00~FF) Data : Write data CS : CMD + LENGTH + ADH + ADL + Data_1 + ... + Data_n Delay : 20ms 5) Check the Diagnostics (DTV country only) ? Buyer model displayed (ex 42LD450) 11-3. Command Set 12. CI+ Key Download [Description] FOS Default write : write Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0, Phase Data write : Model Name and Serial Number write in EEPROM,. 11-4. Method & notice (1) Serial number D/L is using of scan equipment. (2) Setting of scan equipment operated by Manufacturing Technology Group. (3) Serial number D/L must be conformed when it is produced in production line, because serial number D/L is mandatory by D-book 4.0 * Manual Download (Model Name and Serial Number) - If the TV set is downloaded By OTA or Service man, Sometimes model name or serial number is initialized.( Not always) - There is impossible to download by bar code scan, so It need Manual download. 12-1. Download Procedure (1) Press "Power on" button of a service R/C.(Baud rate : 115200 bps) (2) Connect RS232-C Signal Cable. (3) Write CI+ Key through RS-232-C. (4) Check whether the key was downloaded or not at 'In Start' menu. (Refer to below) 1) Press the 'instart' key of ADJ remote controller. 2) Go to the menu '5.Model Number D/L' like below photo. 3) Input the Factory model name(ex 42LD450-TA) or Serial number like photo. 4) Check the model name Instart menu ? Factory name displayed (ex 42LD450-TA) -> Check the Download to CI+ Key value in LGset. 12-2. Check the method of CI+ Key value (1) check the method on Instart menu Copyright ©2011 LG Electronics Inc. All rights reserved. Only for training and service purposes - 12 - LGE Internal Use Only

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

- 12 -
LGE Internal Use Only
Copyright ©2011 LG Electronics Inc. All rights reserved.
Only for training and service purposes
11-2. Signal TABLE
CMD
: A0h
LENGTH
: 85~94h (1~16 bytes)
ADH
: EEPROM Sub Address high (00~1F)
ADL
: EEPROM Sub Address low (00~FF)
Data
: Write data
CS
: CMD + LENGTH + ADH + ADL + Data_1 + ... +
Data_n
Delay
: 20ms
11-3. Command Set
[Description]
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart,
0, Phase
Data write : Model Name and Serial Number write in
EEPROM,.
11-4. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0
* Manual Download (Model Name and Serial Number)
- If the TV set is downloaded By OTA or Service man,
Sometimes model name or serial number is initialized.(
Not always)
- There is impossible to download by bar code scan, so It
need Manual download.
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-TA) or Serial
number like photo.
4) Check the model name Instart menu ? Factory name
displayed (ex 42LD450-TA)
5) Check the Diagnostics (DTV country only) ? Buyer
model displayed (ex 42LD450)
12. CI+ Key Download
12-1. Download Procedure
(1) Press "Power on" button of a service R/C.(Baud rate :
115200 bps)
(2) Connect RS232-C Signal Cable.
(3) Write CI+ Key through RS-232-C.
(4) Check whether the key was downloaded or not at ‘In Start’
menu. (Refer to below)
-> Check the Download to CI+ Key value in LGset.
12-2. Check the method of CI+ Key value
(1) check the method on Instart menu