LG 50PW450 Service Manual - Page 72

Repair Process-Reference data, D. General function defect

Page 72 highlights

Repair Process-Reference data PDP TV Symptom D. General function defect Check Local Key operation Making 2010. 11. 16 전자 - 6-2 A27 IR GND KEY1 KEY2 LED-RED GND SCL SDA GND 3.3V ST NC NC TOUCH_VER_CHK NC NC P+ P- Vol+ Vol- OK Menu Input Power IR & Local key Board for 2/3/4/550 TOOL A27 1.Check connector was inserted properly on Main board and IR board. 2. Check whether appear voltage on multi meter when operate Local switch. ※ Test Condition for case 3 → Check Point: Pin 2,3( Key1,Key2) → TV: power on status → Multi meter: Select DC 10V ⓒ LG Electronics. Inc.2010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

LG Electronics. Inc.2010
Making
전자
- 6-2
PDP TV
Repair Process-Reference data
1.Check connector was inserted properly
on Main board and IR board.
2. Check whether appear voltage on multi meter
when operate Local switch.
Test Condition for case 3
Check Point: Pin 2,3( Key1,Key2)
TV: power on status
Multi meter: Select DC 10V
A27
P+
P-
Vol+
Vol-
OK
Menu
Input
Power
D. General function defect
Check Local Key operation
Symptom
A27
TOUCH_VER_CHK
NC
NC
IR
GND
KEY1
KEY2
LED-RED
GND
SCL
SDA
GND
3.3V ST
NC
NC
IR & Local key Board for 2/3/4/550 TOOL
2010. 11. 16