LG 50PW450 Service Manual - Page 34

D. General Function Problem, Repair Process

Page 34 highlights

Repair Process PDP TV Symptom D. General Function Problem Making Remote control & Local Key & RF emitter checking Revision 2010. 11. 16 전자 - 6-2 9/10 1. Remote controller (R/C) operating error Check R/C itself Operation Normal Y operating? N ☞A26 Check & Repair Cable connection Connector solder Check R/C Operating When turn off light in room If R/C operate, Explain the customer cause is interference from light in room. Check & Replace Battery of R/C Normal operating? N Replace R/C Close ☞A26 Normal N Check B+ 5V operating? On Main B/D ☞A26 Normal Y Check IR Voltage? Output signal Replace Main B/D Normal Y Signal? Y Close N ☞A12 Check 5V on Power B/D Replace Power B/D or Replace Main B/D (Power B/D don't have problem) N Repair/Replace IR B/D 2. Local KEY operating error Check local key Operation Normal Y operating? N ☞A27 Check & Repair Cable connection Connector solder Move Power problem Section Normal N operating? ☞A27 Check Key Output signal Replace Main B/D Normal Y Signal? Y Close N Repair/Replace Local Key B/D 9 ⓒ LG Electronics. Inc.2010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

LG Electronics. Inc.2010
Making
전자
- 6-2
Revision
9/10
PDP TV
Symptom
D. General Function Problem
Y
N
Repair Process
9
1. Remote controller (R/C) operating error
Move
Power problem
Section
2. Local
KEY operating error
Check R/C itself
Operation
Normal
operating?
Normal
operating?
Y
Close
Replace R/C
If R/C operate,
Explain the customer
cause is interference
from light in room.
Check R/C Operating
When turn off light
in room
Check & Replace
Battery of R/C
Check & Repair
Cable connection
Connector solder
Normal
operating?
Check B+ 5V
On Main B/D
A26
Normal
Voltage?
Close
N
N
Check 5V on Power B/D
Replace Power B/D or
Replace Main B/D
(Power B/D don’t have problem)
A12
Check IR
Output signal
Normal
Signal?
N
Y
Repair/Replace
IR B/D
N
A26
Replace
Main B/D
Y
Y
N
Check local
key
Operation
Normal
operating?
Check & Repair
Cable connection
Connector solder
A26
A27
Check Key
Output signal
Y
Normal
operating?
Close
N
Normal
Signal?
Repair/Replace
Local Key B/D
N
Replace
Main B/D
Y
A27
Remote control & Local Key & RF emitter checking
2010. 11. 16