LG GR-J303TS Service Manual - Page 11

Sequential Operation Of Electrical Parts

Page 11 highlights

3-1-12. SEQUENTIAL OPERATION OF ELECTRICAL PARTS Electrical parts such as COMP, defrosting heater at the upper & middle compartment, fan motor at the upper & middle compartment, single motor damper and FRONT-C heater sequentially operate as followers for preventing noise and damage of parts occurred by that various parts operate at the same time in input of initial power on and after test closing (including temporary power failure, either): Function Operation Sequence Remarks When defrosting sensor temperature at the upper compartment is more than 45°C (In purchasing, movement) 0.5 SINGLE 0.3 POWER sec MOTOR sec ON DAMPER ON COMP ON 0.3 FRONT 10 sec -C sec HEATER ON F-FAN ON 4~5 SINGLE sec MOTOR DAMPER OFF 0.5 5~6 sec 3-WAY sec VALVE ON 3-WAY VALVE OFF 0.5 3~6 sec STEPPING sec MOTOR DAMPER ON STEPPING MOTOR DAMPER OFF In initial power on POWER ON 0.5 sec DEFROSTING 0.3 HEATER sec AT UPPER DEFROSTING 4 HEATER sec AT MIDDLE DEFROSTING 0.3 HEATER sec AT UPPER DEFROSTING 0.3 HEATER sec AT MIDDLE FRONT -C HEATER COMPARTMENT ON COMPARTMENT ON COMPARTMENT OFF COMPARTMENT OFF ON When defrosting sensor temperature at the upper compartment is less than 45°C (In power failure, service) 4 FRONT 4 SINGLE 0.3 0.3 FRONT sec -C sec MOTOR sec COMP sec -C HEATER DAMPER ON HEATER OFF ON ON 10 UPPER sec COMPARTMENT FAN ON 10~30 sec SINGLE MOTOR DAMPER OFF 0.5 5~6 sec 3-WAY sec 3-WAY VALVE VALVE ON OFF 0.5 STEPPING 3~6 STEPPING sec MOTOR sec MOTOR DAMPER DAMPER ON OFF No initial operation is done if error occurs during operation. - 11 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

3-1-12. SEQUENTIAL OPERATION OF ELECTRICAL PARTS
Electrical parts such as COMP, defrosting heater at the upper & middle compartment, fan motor at the upper & middle
compartment, single motor damper and FRONT-C heater sequentially operate as followers for preventing noise and
damage of parts occurred by that various parts operate at the same time in input of initial power on and after test closing
(including temporary power failure, either):
- 11 -
Function
Operation Sequence
Remarks
In initial power on
When
defrosting
sensor
temperature at
the upper
compartment is
more than 45°C
(In purchasing,
movement)
When
defrosting
sensor
temperature at
the upper
compartment is
less than 45°C
(In power
failure, service)
No initial
operation is
done if error
occurs
during
operation.
POWER
ON
SINGLE
MOTOR
DAMPER
ON
COMP
ON
F-FAN
ON
SINGLE
MOTOR
DAMPER
OFF
5~6
sec
0.5
sec
3-WAY
VALVE
ON
3-WAY
VALVE
OFF
3~6
sec
0.5
sec
FRONT
-C
HEATER
ON
0.5
sec
0.3
sec
10
sec
0.3
sec
4~5
sec
STEPPING
MOTOR
DAMPER
ON
STEPPING
MOTOR
DAMPER
OFF
POWER
ON
DEFROSTING
HEATER
AT UPPER
COMPARTMENT
ON
DEFROSTING
HEATER
AT MIDDLE
COMPARTMENT
ON
DEFROSTING
HEATER
AT UPPER
COMPARTMENT
OFF
DEFROSTING
HEATER
AT MIDDLE
COMPARTMENT
OFF
FRONT
-C
HEATER
ON
FRONT
-C
HEATER
OFF
SINGLE
MOTOR
DAMPER
ON
COMP
ON
FRONT
-C
HEATER
ON
0.5
sec
0.3
sec
4
sec
0.3
sec
0.3
sec
4
sec
4
sec
0.3
sec
0.3
sec
10
sec
10~30
sec
UPPER
COMPARTMENT
FAN
ON
SINGLE
MOTOR
DAMPER
OFF
0.5
sec
5~6
sec
3-WAY
VALVE
ON
3-WAY
VALVE
OFF
0.5
sec
3~6
sec
STEPPING
MOTOR
DAMPER
ON
STEPPING
MOTOR
DAMPER
OFF