3-2-6. TEMPERATURE SENSING CIRCUIT ⃄ (LED:6871JB1400, LCD:6871JB1399) Above circuits consist of the upper sensor, middle sensor, lower sensor for adjusting setup temperature at the upper, middle and lower compartment, the ambient temperature sensor to detect ambient air temperature, the upper defrost sensor and the middle defrost sensor attached to the evaporator at the upper, middle compartment to detect the defrost return temperature. Status in short or open are as follows: Sensor Check points Normal (-30 °C ~ 50 °C) Ambient temp. Sensor Upper Sensor Middle Sensor Lower Sensor Upper Defrost Sensor Middle Defrost Sensor POINT ⃄Voltage POINT ⃅Voltage POINT ⃆Voltage POINT ⃇Voltage POINT ⃈Voltage POINT ⃉Voltage 0.5V ~ 4.5V In Short 0V In Open 5V - 18 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

3-2-6. TEMPERATURE SENSING CIRCUIT
Above circuits consist of the upper sensor, middle sensor, lower sensor for adjusting setup temperature at the upper, middle
and lower compartment, the ambient temperature sensor to detect ambient air temperature, the upper defrost sensor and
the middle defrost sensor attached to the evaporator at the upper, middle compartment to detect the defrost return
temperature. Status in short or open are as follows:
- 18 -
(
)
(LED:6871JB1400, LCD:6871JB1399)
Sensor
Check points
Normal (-30 °C ~ 50 °C)
In Short
In Open
Ambient temp. Sensor
Upper Sensor
Middle Sensor
Lower Sensor
Upper Defrost Sensor
Middle Defrost Sensor
0.5V ~ 4.5V
0V
5V
POINT
Voltage
POINT
Voltage
POINT
Voltage
POINT
Voltage
POINT
Voltage
POINT
Voltage