Lenovo ThinkCentre M58e Hardware Maintenance Manual - Page 66
Assure Asset Security Enabled, Hard Disk Drive Cable
View all Lenovo ThinkCentre M58e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Diagnostic Error Code 175-199-XXX Thermal Sensor(s) test failed, cause unknown 175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 185-000-XXX Asset Security Test Passed 185-XXX-XXX Asset Security failure 185-278-XXX Asset Security Chassis Intrusion 201-000-XXX System Memory Test Passed 201-XXX-XXX System Memory error 202-000-XXX System Cache Test Passed 202-XXX-XXX System Cache error 206-000-XXX Diskette Drive Test Passed 206-XXX-XXX Diskette Drive error 215-000-XXX CD-ROM Drive Test Passed 215-XXX-XXX CD-ROM Drive error 217-000-XXX Hard Disk Drive Test Passed 217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error FRU/Action 1. See "Undetermined problems" on page 65 2. Flash the system and re-test. See "Flash update procedures" on page 521 3. Replace component under function test 1. Check fans 2. Check Power supply voltages 3. Microprocessor 4. System board No action 1. Flash system 2. System board 1. Assure Asset Security Enabled 2. C2 Cover Switch 3. System board No action 1. Replace the memory module called out by the test 2. System board No action 1. Cache, if removable 2. System board 3. Microprocessor No action 1. Diskette Drive Cable 2. Check power supply voltages 3. Diskette drive 4. System board No action 1. CD-ROM Drive Cable 2. Check power supply voltages 3. CD-ROM drive 4. System board No action 1. Hard Disk Drive Cable 2. Check power supply voltages 3. Reseat the hard disk drive cable 4. Hard Disk drive (IDE) 5. System board 60 ThinkCentre Hardware Maintenance Manual